Eurosurveillance
-
In the absence of a vaccine or specific treatments for Ebola virus disease (EVD), early identification of cases is crucial for the control of EVD epidemics. We evaluated a new extraction kit (SpeedXtract (SE), Qiagen) on sera and swabs in combination with an improved diagnostic reverse transcription recombinase polymerase amplification assay for the detection of Ebola virus (EBOV-RT-RPA). The performance of combined extraction and detection was best for swabs. ⋯ Of 928 post-mortem swabs, 120 tested positive, and the combined SE and EBOV-RT-RPA yielded a sensitivity and specificity of 100% in reference to one real-time RT-PCR assay. Another widely used real-time RT-PCR was much less sensitive than expected. Results were provided very fast within 30 to 60 min, and the field deployment of the mobile laboratory helped improve burial management and community engagement.
-
From June 2014 through February 2015, respiratory samples from 130 Danish patients were screened for enterovirus D68 (EV-D68). Fourteen EV-D68 cases were detected, of which 12 presented with respiratory symptoms, and eight had known underlying disease. The median age of EV-D68 cases was three years (interquartile range: 0–30 years). Acute flaccid paralysis (AFP) was not detected although Danish EV-D68 strains showed > 98% nt identity with EV-D68-strains from AFP cases from the United States and France.