The Journal of thoracic and cardiovascular surgery
-
J. Thorac. Cardiovasc. Surg. · May 1977
Case ReportsSepticemia secondary to impacted infected pacemaker wire. Successful treatment by removal with cardiopulmonary bypass.
Infection of an intravenous pacemaker electrode developed in a 78-year-old man after multiple replacements and revisions of the pulse generator and the pacemaker lead. Spread of the infective process to the endocardium was followed by septicemia with Serratia marcescens and Staphyloccus epidermids. Failure of medical treatment and external traction on the pacemaker electrode led to thoracotomy and removal of the pacemaker electrode wires with the use of extracorporeal circulation. ⋯ Cultures from the endocardium removed with the electrode rendered the same organisms as cultured preoperatively. There has been no recurrence after 2 years following the removal of the infected electrodes. Although the problem described herein is not frequently found, radical treatment becomes necessary whenever infection and septicemia develop.
-
J. Thorac. Cardiovasc. Surg. · May 1977
Monitoring of intraoperative heparinization and blood loss following cardiopulmonary bypass surgery.
Two protocols of heparin management during cardiopulmonary bypass were compared to assess the role of the activated clotting time (ACT) in relation to postoperative blood loss. The study was divided into two groups: Group I, the control group, in which 3 mg. of heparin per kilogram was given as the initial dose and maintained at a dose of 1.5 mg. per kilogram every 45 minutes during cardiopulmonary bypass, and Group II, in which the initail dose of heparin was 2 mg. per kilogram and additional dosage were based upon the ACT. ⋯ Thus, when patients are given too much heparin, as in our control group, the effectiveness of protamine is decreased. We would like to stress the value of the ACT in controlling heparin administration as well as postoperative blood loss in cardiopulmonary bypass surgery.
-
J. Thorac. Cardiovasc. Surg. · Mar 1977
Comparative StudyMonitoring of cardiac output by thermodilution after open-heart surgery.
One hundred twenty-five separate cardiac output determinations were obtained after open-heart surgery in 10 patients by simultaneous use of thermodilution and dye-dilution techniques. Mean thermodilution cardiac output was 1.6 per cent greater than mean dye-dilution cardiac output (5.24 versus 5.16 L. per minute). Reproducibility of thermodilution cardiac output (coefficient of variation, 8.6 per cent) was superior to that of dye-dilution cardiac output (coefficient of variation, 12.3 per cent) for outputs ranging from 2.5 to 8.7 L. per minute (p less than 0.001). ⋯ The results indicate that thermodilution cardiac output is a valid method for determining cardiac output in the rapidly changing clinical setting following cardiopulmonary bypass. Clinical applications of this technique include evaluation of the efficacy of inotropic agents, effectiveness of intra-aortic balloon counterpulsation, and status of the low output syndrome postoperatively. Routine use in patients with Class III or IV cardiac disease appears justified.
-
J. Thorac. Cardiovasc. Surg. · Mar 1977
Case ReportsRetention of pacemaker electrode complicated by Serratia marcescens septicemia. Removal with total cardiopulmonary bypass.
A case in which Serratia marcescens septicemia complicated the insertion of a transvernous pacemaker unit is reported. Appropriate antibiotic therapy and removal of the pacemaker electrode are two essential steps to achieve a complete cure in this stimulation. Open cardiotomy with total cardiopulmonary bypass provides a safe approach for withdrawal of an incarcerated electrode and is justified because of the lethal potential of systemic Serratia infections, particularly those superimposed on intracardiac prostheses.
-
J. Thorac. Cardiovasc. Surg. · Feb 1977
Effects of coronary bypass surgery on the electrical activity of revascularized myocardium. Immediate and early postoperativeobservations.
The effect of myocardial revascularization on bipolar epicardial electrograms was recorded with fixed wire electrodes from revascularized left ventricular sites and from control sites on the right ventricle. Studies were performed during and after surgery in 19 patients undergoing aorta-coronary bypass grafting for occlusive coronary artery disease and in 6 additional patients having aortic valve replacement for isolated aortic valve disease. In the latter 6 patients, neither left nor right ventricular electrogram voltage changed immediately following aortic valve replacement; however, left ventricular electrogram voltage gradually decreased for 5 days postoperatively. ⋯ These observed changes did not correlate with preoperative hemodynamics, number of grafts, graft flow rate, aortic cross-clamp time, cardiopulmonary bypass time, and the early postoperative course. These preliminary observations suggest that coronary bypass grafting does affect the electrophysiological state of the revascularized myocardium. However, the mechanism by which it occurs and its clinical implications remain to be determined.