Plos One
-
Systematically evaluating scientific literature is a time consuming endeavor that requires hours of coding and rating. Here, we describe a method to distribute these tasks across a large group through online crowdsourcing. Using Amazon's Mechanical Turk, crowdsourced workers (microworkers) completed four groups of tasks to evaluate the question, "Do nutrition-obesity studies with conclusions concordant with popular opinion receive more attention in the scientific community than do those that are discordant?" 1) Microworkers who passed a qualification test (19% passed) evaluated abstracts to determine if they were about human studies investigating nutrition and obesity. ⋯ Direct microworker costs totaled $221.75, (estimated cost at minimum wage: $312.61). We discuss important points to consider to ensure good quality control and appropriate pay for microworkers. With good reliability and low cost, crowdsourcing has potential to evaluate published literature in a cost-effective, quick, and reliable manner using existing, easily accessible resources.
-
To describe nationally representative outcomes of physical abuse injuries in children necessitating Emergency Department (ED) visits in United States. The impact of various injuries on mortality is examined. We hypothesize that physical abuse resulting in intracranial injuries are associated with worse outcome. ⋯ In this large cohort of physically abused children, younger age, females and intracranial or crushing/internal injuries were independent predictors of mortality. Identification of high risk cohorts in the ED may enable strengthening of existing screening programs and optimization of outcomes.
-
Pulmonary endarterectomy (PEA) is established for the treatment of chronic thromboembolic pulmonary hypertension (CTEPH). Recently, percutaneous transluminal pulmonary angioplasty (PTPA) has been added for peripheral-type CTEPH, whose lesions exist in segmental, subsegmental, and more distal pulmonary arteries. A shift in clinical practice of interventional therapies occurred in 2009 (first mainly PEA, later PTPA). We examined the latest clinical outcomes of patients with CTEPH. ⋯ The patients who underwent interventional therapies had better results than those treated only with drugs. The availability of both of these operative and catheter-based interventional therapies leads us to expect the dawn of a new era of therapeutic strategies for CTEPH.
-
Few studies have been conducted specifically on the dense connective tissue located in the posterior medial part of the cervical epidural space. This study was undertaken to examine the presence of this connection between the cervical dura mater and the posterior wall of spinal canal at the level of C1-C2. 30 head-neck specimens of Chinese adults were used. Gross dissection was performed on the suboccipital regions of the 20 specimens. ⋯ These two structures, TBNL and VDL, firmly link the posterior aspect of cervical dura mater to the rear of the atlas-axis and the nuchal region. According to these findings, the authors speculated that the movements of the head and neck are likely to affect the shape of the cervical dural sleeve via the TBNL and VDL. It is hypothesized that the muscles directly associated with the cervical dural sleeve, in the suboccipital region, may work as a pump providing an important force required to move the CSF in the spinal canal.
-
Because of the limitations of existing methods and techniques for directly obtaining real-time blood data, no accurate microflow in vivo real-time analysis method exists. To establish a novel technical platform for real-time in vivo detection and to analyze average blood pressure and other blood flow parameters, a small, accurate, flexible, and nontoxic Fabry-Perot fiber sensor was designed. The carotid sheath was implanted through intubation of the rabbit carotid artery (n = 8), and the blood pressure and other detection data were determined directly through the veins. ⋯ The average ambulatory blood pressure measured by the fiber sensor exhibited a negative correlation with the quantity of blood platelets (correlation coefficient of -0.839, P<0.05). The novel fiber sensor can thus obtain in vivo blood pressure data accurately, stably, and in real time; the sensor can also determine the content and status of the blood flow to some extent. Therefore, the fiber sensor can obtain partially real-time vascular rheology information and may thus enable the early diagnosis of blood rheology disorders and diseases.