Pediatr Crit Care Me
-
Pediatr Crit Care Me · Nov 2012
"I was able to still be her mom"--parenting at end of life in the pediatric intensive care unit.
The death of a child in the pediatric intensive care unit is perhaps one of the most devastating and challenging experiences a parent can ever endure. This article examines how parents of children dying in the pediatric intensive care unit understood their role and discusses implications for clinical care and policy. ⋯ Parents' ability to fulfill the essential features of their role as parents of children dying in the pediatric intensive care unit shapes how they perceive the quality of the experience. Pediatric intensive care unit clinical care and policies can and should uphold and protect these features enabling parents to feel that, despite the outcome, they had done their best on behalf of their children.
-
Pediatr Crit Care Me · Nov 2012
Comparative StudyUltrasound-guided femoral vein catheterization in neonates with cardiac disease*.
To describe a novel technique for real-time, ultrasound-guided femoral vein catheterization in neonates with cardiac disease, and to compare it to a contemporaneous cohort of neonates undergoing femoral vein central venous line placement via landmark technique. ⋯ This novel long-axis real-time ultrasound technique facilitates placement of femoral vein central venous line in critically ill neonates with cardiac disease at a higher rate of success with fewer attempts and lower occurrence of complications when compared with the landmark technique.
-
Pediatr Crit Care Me · Nov 2012
Exposure to di(2-ethylhexyl) phthalate in premature neonates in a neonatal intensive care unit in Taiwan.
Neonates are exposed to high levels of di(2ethylhexyl) phthalate through numerous medical procedures in the neonatal intensive care unit. Our aim was to assess the contribution of specific medical devices to the di(2-ethylhexyl) phthalate exposure of neonates. ⋯ These data suggest that polyvinyl chloride-containing devices are the major defining factor in di(2-ethylhexyl) phthalate exposure levels in neonates in the neonatal intensive care unit. We urge the use of polyvinyl chloride-free or alternative materials in medical devices, especially for endotracheal tubes, orogastric tubes, nasogastric tubes, and intravenous tubing in the neonatal intensive care unit. The health effects of high di(2-ethylhexyl) phthalate exposure on premature neonates in the neonatal intensive care unit is worthy of further investigation.
-
Pediatr Crit Care Me · Nov 2012
Predictors of failure in infants with viral bronchiolitis treated with high-flow, high-humidity nasal cannula therapy*.
Viral bronchiolitis is an acute infection and inflammatory disease of the respiratory tract, with infants typically presenting with the most severe symptoms. Medical management of bronchiolitis is mostly supportive. Several preliminary studies suggest potential benefit from the use of high-flow nasal cannula systems. Although high-flow nasal cannula is a well-established modality in the newborn intensive care unit, its use in the pediatric intensive care unit for acute respiratory failure is far less established. The objective of this study was to identify any laboratory and clinical variables that may predict high-flow nasal cannula failure in management of bronchiolitis in the pediatric intensive care unit. ⋯ History of prematurity and the patient's age did not increase a patient's risk of failure. Nonresponders to high-flow nasal cannula therapy were on the onset, more hypercarbic, were less tachypnic prior to the start of high-flow nasal cannula, and had no change in their respiratory rate after the initiation of high-flow nasal cannula therapy. Nonresponders had higher pediatric risk of mortality scores in the first 24 hrs.
-
Pediatr Crit Care Me · Nov 2012
The need for and feasibility of a pediatric ventilation trial: reflections on a survey among pediatric intensivists*.
To explore what design would be reasonable, acceptable, and feasible for a pediatric trial investigating the effect of low tidal volume ventilation. ⋯ Actual expert opinion favored investigating the effect of 6 mL/kg vs.10 mL/kg on mortality. Such a design suffers from various serious criticisms. Therefore, and in our opinion, a pediatric Acute Respiratory Distress Syndrome Network trial is not realistic.