Cochrane Db Syst Rev
-
Cochrane Db Syst Rev · Feb 2024
ReviewInitial arch wires used in orthodontic treatment with fixed appliances.
Initial arch wires are the first arch wires inserted into fixed appliance at the beginning of orthodontic treatment. With a number of different types of orthodontic arch wires available for initial tooth alignment, it is important to understand which are most efficient and which cause the least amount of root resorption and pain during the initial aligning stage of treatment. This is the third update of a Cochrane review first published in 2010. ⋯ Superelastic NiTi wires probably produce slightly more pain after one day than thermoelastic NiTi wires, and single-strand superelastic NiTi wires probably have a lower alignment rate over four weeks compared with coaxial superelastic NiTi wires. All other evidence on alignment rate, root resorption, time to alignment, and pain is of low or very low certainty in all comparisons. Therefore, there is insufficient evidence to determine whether any particular arch wire material or size is superior to any other. The findings of this review are imprecise and unreliable; well-designed larger studies are needed to give better estimates of the benefits and harms of different arch wires. Orthodontists should exercise caution when interpreting the findings of this review and be prepared to adapt their treatment plans based on individual patient needs.
-
The coronavirus disease 2019 (COVID-19) pandemic caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) continues to challenge the health workforce and societies worldwide. Favipiravir was suggested by some experts to be effective and safe to use in COVID-19. Although this drug has been evaluated in randomized controlled trials (RCTs), it is still unclear if it has a definite role in the treatment of COVID-19. ⋯ The low- to very low-certainty evidence means that we do not know whether favipiravir is efficacious in people with COVID-19 illness, irrespective of severity or admission status. Treatment with favipiravir may result in an overall increase in the incidence of adverse events but may not result in serious adverse events.
-
Meibomian gland dysfunction (MGD) is the most common underlying cause of dry eye disease (DED). MGD leads to pathological alteration of the composition or quantity of meibum, or both, which subsequently results in tear evaporation and the typical signs and symptoms associated with DED. The LipiFlow Thermal Pulsation System (LipiFlow) is a medical device used to treat MGD in office; however, it is unclear if LipiFlow can outperform other DED treatments. ⋯ LipiFlow performs similarly to other commonly used DED treatments with regard to DED signs and symptoms. The best available evidence was deemed to have a high level of bias, leading to low or very low certainty evidence. Additional research with adequate masking, a standardized testing methodology, and a sample representative of the MGD population is therefore needed before any firm conclusions can be drawn regarding comparative benefits and harms.
-
IgA nephropathy (IgAN) is the most common primary glomerular disease, with approximately 20% to 40% of patients progressing to kidney failure within 25 years. Non-immunosuppressive treatment has become a mainstay in the management of IgAN by improving blood pressure (BP) management, decreasing proteinuria, and avoiding the risks of long-term immunosuppressive management. Due to the slowly progressive nature of the disease, clinical trials are often underpowered, and conflicting information about management with non-immunosuppressive treatment is common. This is an update of a Cochrane review, first published in 2011. ⋯ Available RCTs focused on a diverse range of interventions. They were few, small, and of insufficient duration to determine potential long-term benefits on important kidney and cardiovascular outcomes and harms of treatment. Antihypertensive agents appear to be the most beneficial non-immunosuppressive intervention for IgAN. The antihypertensives examined were predominantly angiotensin-converting enzyme inhibitors or angiotensin receptor blockers. The benefits of RAS inhibition appear to outweigh the harms in patients with IgAN. The certainty of the evidence of RCTs demonstrating a benefit of tonsillectomy to patients with Japanese patients with IgAN was low. In addition, these findings are inconsistent across observational studies in people with IgAN of other ethnicities; hence, tonsillectomy is not widely recommended, given the potential harm of therapy. The RCT evidence is insufficiently robust to demonstrate efficacy for the other non-immunosuppressive treatments evaluated here.
-
Cochrane Db Syst Rev · Jan 2024
ReviewDeep neuromuscular blockade in adults undergoing an abdominal laparoscopic procedure.
Laparoscopic surgery is the preferred option for many procedures. To properly perform laparoscopic surgery, it is essential that sudden movements and abdominal contractions in patients are prevented, as it limits the surgeon's view. There has been a growing interest in the potential beneficial effect of deep neuromuscular blockade (NMB) in laparoscopic surgery. Deep NMB improves the surgical field by preventing abdominal contractions, and it is thought to decrease postoperative pain. However, it is uncertain if deep NMB improves intraoperative safety and thereby improves clinical outcomes. ⋯ There was insufficient evidence to draw conclusions about the effects of deep NMB compared to moderate NMB on all-cause mortality and serious adverse events. Deep NMB likely results in little to no difference in health-related quality of life and duration of surgery compared to moderate NMB, and it may have no effect on the length of hospital stay. Due to the very low-certainty evidence, we do not know what the effect is of deep NMB on non-serious adverse events, pain scores, or readmission rates. Randomised clinical trials with adequate reporting of all adverse events would reduce the current uncertainties. Due to the low number of identified trials and the very low certainty of evidence, we do not know what the effect of deep NMB on serious adverse events is compared to shallow NMB and no NMB. We found no trials evaluating mortality and health-related quality of life.