Respiratory care
-
Exercise intolerance is the hallmark of COPD. Static lung hyperinflation and increased dynamic hyperinflation during exercise are associated with reduced functional capacity in COPD patients. Inspiratory capacity correction for the total lung capacity, defined as inspiratory fraction (IF), may be functionally more representative than other traditional indices in these patients. ⋯ Compared to FEV1, IF is a robust factor to reflect lung hyperinflation and to estimate the exercise capacity of subjects with stable moderate to severe COPD.
-
Closed pleural biopsy (CPB) in patients with malignant pleural effusion is less sensitive than cytology. Ultrasound-assisted CPB allows biopsies to be performed in the lower thoracic parietal pleura, where secondary spread from pleural metastases is initially more likely to be found. We analyzed whether choosing the point of entry for CPB with thoracic ultrasound assistance influences the diagnostic yield in malignant pleural effusion. ⋯ Selecting the point of entry for CPB using thoracic ultrasound increases the likelihood of obtaining pleural tissue and the diagnostic yield, but without statistical significance. We recommend ultrasound-assisted CPB to investigate pleural effusion, since the diagnostic yield of a pleural biopsy with an Abrams needle increased by > 17% in subjects with malignant pleural effusion.
-
Therapeutic gases and other modalities delivered by inhalation may affect the accuracy of capnographic measurements in 2 ways. First is the specificity of the measurement of CO2 within the device, and second is the dilution effect of supplemental gases in the ambient air during CO2 sampling by the device. Our goal was to determine if variables such as inhaled gas composition, gas flows delivered via non-rebreather mask, and mouth open or closed affect measurements of end-tidal CO2 pressure (PETCO2) measured with the Capnostream 20 capnograph. ⋯ In normal subjects, PETCO2 measurements with the Capnostream 20 were not affected by heliox or gas flow at 10 or 15 L/min through a non-rebreathing mask.
-
Comparative Study
Effects of Condensate in the Exhalation Limb of Neonatal Circuits on Airway Pressure During Bubble Continuous Positive Airway Pressure.
Bubble CPAP is frequently used in spontaneously breathing infants with lung disease. Often bubble CPAP systems lack pressure alarms and pressure-release valves. We observed a large volume of condensate in the exhalation limb of a patient circuit and conducted a series of experiments to test the hypothesis that accumulated condensate could affect delivered pressures. ⋯ Condensate in the exhalation limb of the patient circuit during bubble CPAP can significantly increase pressure delivered to the patient. The back and forth movement of this fluid causes oscillations in airway pressure that are much greater than the oscillations created by gas bubbling out the exhalation tube into the water bath. We recommend continuously monitoring pressure at the nasal airway interface, placing an adjustable pressure-relief valve in the circuit, set to 5 cm H2O above the desired mean pressure, and emptying fluid from the exhalation limb every 2-3 hours.
-
Case Reports
Gorham Syndrome with Post-operative Respiratory Failure and Requiring Prolonged Mechanical Ventilation.
Gorham syndrome is a rare disease that presents as progressive osteolysis, and may affect any part of the skeleton. The pathologic process involves the replacement of normal bone by aggressively expanding but non-neoplastic vascular tissue, resulting in massive osteolysis of the adjacent bone. If the spine and ribs are affected, the subsequent kyphosis and chest wall deformity may cause severe restrictive ventilatory impairment. ⋯ He underwent spinal surgery but could not be extubated after surgery. Postoperative left lower lung pneumonia and respiratory failure required prolonged mechanical ventilation. After a weaning program of pressure support ventilation and T-piece spontaneous breathing trials, he was successfully weaned from mechanical ventilation.