Respiratory care
-
Cardiovascular autonomic neuropathy is one of the factors implicated in the high morbidity and mortality rate in patients with COPD. Thus, several studies and nonsystematic reviews have increasingly reported autonomic function impairment in these subjects. For a better understanding, this systematic review was performed to evaluate not only the evidence for autonomic function impairment, but also factors influencing it. ⋯ The results of this review highlight relevant clinical messages for clinicians and other health-care providers regarding the role autonomic function can play as an important physiological marker for prognostication and stratification. Hence, autonomic function outcomes should be identified and considered during management of patients with COPD. Moreover, this review can serve as basis for future research aimed at assessing the interventions for autonomic function abnormalities in these patients.
-
Mask ventilation is lifesaving, especially in cases of difficult intubation. Many publications have offered distinct techniques for optimizing mask ventilation. ⋯ We divide difficult mask ventilation into 3 broad categories based on etiology: inadequate mask seal, increased airway resistance, and decreased respiratory compliance. Published strategies for overcoming difficulty are presented and organized by etiology.
-
Randomized Controlled Trial Comparative Study
Comparison of the Feasibility and Safety of Nasotracheal Suctioning With Curved Edge Catheter Versus Conventional Suction Catheter in Critically Ill Subjects: A Prospective Randomized Crossover Trial.
Nasotracheal suctioning (NTS) is accomplished by inserting a suction catheter into the trachea through the nasopharynx. It is a useful procedure in critically ill patients whose ability to cough and mobilize secretions is impaired. Ιt was assumed that using a suction catheter with an angular tip would facilitate entry into the trachea. The primary outcome was the success rate and the ease of insertion by using a curved edge catheter (Tiemann type) compared with a conventional suction catheter. The secondary outcome was the monitoring of subject's vital signs during the intervention. ⋯ It is more likely that tracheal access will be achieved using a curved edge catheter. A shorter process time and fewer attempts are required for successful NTS using a curved edge catheter, and it seems to be an equally safe procedure. (ClinicalTrials.gov registration NCT02261428.).
-
Randomized Controlled Trial Comparative Study
A Randomized Controlled Trial of 2 Inhalation Methods When Using a Pressurized Metered Dose Inhaler With Valved Holding Chamber.
Information on the comparative efficacy of single deep breathing versus tidal breathing for inhaled asthma medications is limited, although such information can be of much use for the treatment of patients suffering from asthma. The objective of the present study was to compare the relative difference in improvement in peak expiratory flow (PEF) with single maximal inhalation with breath-holding versus 5 tidal breaths during inhalation of salbutamol from a pressurized metered dose inhaler (pMDI) with valved holding chamber (VHC) in children 5-15 y of age with asthma. ⋯ Single maximal inhalation with a breath-hold technique is not superior to tidal breathing for improvement in PEF following salbutamol inhalation. Either method may be used in children between 5 and 15 y of age. (India's Clinical Trials Registry CTRI/2013/04/003559.).
-
Comparative Study
CPAP Devices for Emergency Prehospital Use: A Bench Study.
CPAP is frequently used in prehospital and emergency settings. An air-flow output minimum of 60 L/min and a constant positive pressure are 2 important features for a successful CPAP device. Unlike hospital CPAP devices, which require electricity, CPAP devices for ambulance use need only an oxygen source to function. The aim of the study was to evaluate and compare on a bench model the performance of 3 orofacial mask devices (Ventumask, EasyVent, and Boussignac CPAP system) and 2 helmets (Ventukit and EVE Coulisse) used to apply CPAP in the prehospital setting. ⋯ Air-flow output, pressure applied, FIO2 delivered, device oxygen consumption, and ability to maintain air flow at 60 L/min differed significantly among the CPAP devices tested. Only the EasyVent and EVE Coulisse achieved the required minimum level of air-flow output needed to ensure an effective therapy under all CPAP conditions.