Respiratory care
-
The N95 filtering facepiece respirator (FFR) is the most popular individual protective device to reduce exposure to particulate matter. However, concerns have been raised with regard to its use because it can increase respiratory resistance and dead space. Therefore, this study assessed the safety of N95 use in patients with COPD and air-flow limitation. ⋯ This study demonstrated that subjects with COPD who had modified Medical Research Council dyspnea scale scores ≥ 3 or FEV1 < 30% predicted wear N95s only with care.
-
Relevant publications related to medicinal and toxic aerosols are discussed in this review. Treatment of COPD includes a combination of long-acting bronchodilators and long-acting muscarinic antagonists. A combination of aclidinium bromide and formoterol fumarate was approved in the United States. ⋯ Surgical masks were well tolerated and significantly decreased the burden of aerosolized bacteria generated by coughing in adults with cystic fibrosis. Inhaled liposomal amikacin in addition to guideline-based therapy was reported to be superior to guideline-based therapy alone in achieving negative sputum cultures in adult subjects with Mycobacterium avium complex pulmonary disease. During 2019, lung injury associated to e-cigarette or vaping was reported, including 60 casualties.
-
Respiratory support of the critically ill neonate has steadily shifted from invasive to noninvasive forms of support. There have recently been a number of important advances in our understanding of the changes to neonatal resuscitation practices as they pertain to clinically important outcomes, mechanisms of gas exchange for high-flow nasal cannula, and best use of noninvasive ventilation and predicting response. ⋯ Recently, volume-targeted ventilation, high-frequency ventilation, and different methods of assessing weaning and extubation have been investigated. This review summarizes a number of important advances that have been made in the management of prematurity and neonatal respiratory distress syndrome.
-
Randomized Controlled Trial
High-Flow Nasal Cannula May Not Reduce the Re-Intubation Rate after Extubation in Respiratory Failure Compared With a Large-Volume Nebulization-Based Humidifier.
High-flow nasal cannula (HFNC) therapy may reduce the re-intubation rate compared with conventional oxygen therapy. However, HFNC has not been sufficiently compared with conventional oxygen therapy with a heated humidifier, even though heated humidification is beneficial for facilitating airway clearance. ⋯ Compared with a large-volume nebulization-based humidifier, HFNC may not reduce the re-intubation rate within 7 d. However, because of insufficient statistical power, further studies are needed to reach a conclusion.
-
Randomized Controlled Trial
Esophageal Pressure Versus Gas Exchange to Set PEEP During Intraoperative Ventilation.
Pneumoperitoneum and Trendelenburg position affect respiratory system mechanics and oxygenation during elective pelvic robotic surgery. The primary aim of this randomized pilot study was to compare the effects of a conventional low tidal volume ventilation with PEEP guided by gas exchange (VGas-guided) versus low tidal volume ventilation tailoring PEEP according to esophageal pressure (VPes-guided) on oxygenation and respiratory mechanics during elective pelvic robotic surgery. ⋯ Oxygenation and respiratory system mechanics were improved when applying a ventilatory strategy tailoring PEEP to equalize expiratory transpulmonary pressure in subjects undergoing pelvic robotic surgery compared to a VGas-guided approach. (ClinicalTrials.gov registration NCT03153592).