BMC anesthesiology
-
In adult respiratory distress syndrome (ARDS), life-threatening hypoxemia may occur, dictating the need for differentiated ventilator strategies. Pronounced consolidation and/or atelectasis have been well documented in ARDS, but the contribution of regional perfusion to oxygenation has been poorly addressed. Evidence has accumulated that, in ARDS, regional perfusion is extremely variable and may affect oxygenation, independently from the amount of atelectatic-consolidated lung regions. ⋯ Lung ultrasound and novel algorithms for electrical impedance tomography represent new promising techniques that could enable physicians to assess the distribution of pulmonary blood flow at the bedside. In ARDS, we cannot afford missing regional lung perfusion. Please see related article: http://dx.doi.org/10.1186/s12871-015-0013-0.
-
Comparative Study Clinical Trial
Time impact on non-activated and kaolin-activated blood samples in thromboelastography.
The correct methodology of thrombelastography might be influenced by elapsing time. In our study we investigated kaolin activated citrated samples together with non-activated citrated samples in relation to the elapsed times of 0, 15 and 30 minutes to compare both methods and to find out if there is an impact of time on results of thrombelastography. ⋯ The non-activated citrated method seems to be reliable and suitable for thrombelastography in non-emergency cases (planned surgical procedures) when we have time to wait 15-30 minutes to get results. In urgent situations a rapid thrombelastography test should be preferred. Although the kaolin-activated method can also be used, results must be interpreted with caution.
-
We report the peculiar case of a patient with a retained large epidural catheter fragment, incidentally found 12 years after its placement. Our primary aim is to emphasize how the breakage and retention of even exceptionally large portions of this device can go undetected. The patient can be completely asymptomatic and, with no clue that such a foreign body exists, the presentation of its potential complications can be subtle and misleading. To our knowledge, this is the first reported case of the incidental discovery of such a large fragment so many years after its placement. No consensus exists about how to handle this complication, therefore our report adds to the amount of available evidence. ⋯ Breakage of the epidural catheter with fragment retention is a known complication of this device, possibly leading to devastating sequelae. The fragment can go undetected for years. In this case our finding was incidental and the patient was asymptomatic. However, in the event a neurologic complication arose, the identification of the unknowingly retained epidural as the causative agent could have been difficult and delayed, with potential harm to the patient.
-
Observational Study
Abdominal circumference but not the degree of lumbar flexion affects the accuracy of lumbar interspace identification by Tuffier's line palpation method: an observational study.
Lumbar puncture for spinal or epidural anesthesia is commonly performed by palpating bony landmarks, but identification of the desired intervertebral level is often inaccurate. It is unclear whether such inaccuracy is related to patient factors, such as body mass index and degree of lumbar flexion. We hypothesized that overweight patients and patients with less of an ability to hyperflex their lumbar spines are prone to inaccurate lumbar spinous intervertebral level identification. ⋯ Patients' abdominal circumference, body mass index, and age are factors that may impact the accuracy of lumbar level identification. Tuffier's line, as identified by palpation, does not seem to be a reliable landmark for proper lumbar interspace identification in all cases.
-
An increasing number of conditions appear to benefit from control and modulation of temperature, but available techniques to control temperature often have limitations, particularly in smaller patients with high surface to mass ratios. We aimed to evaluate a new method of temperature modulation with an esophageal heat transfer device in a pediatric swine model, hypothesizing that clinically significant modulation in temperature (both increases and decreases of more than 1°C) would be possible. ⋯ An esophageal heat transfer device successfully modulated the temperature in a pediatric swine model. This approach to temperature modulation may offer a useful new modality to control temperature in conditions warranting temperature management (such as maintenance of normothermia, induction of hypothermia, fever control, or malignant hyperthermia).