⋯ Ultrasound guidance for popliteal nerve block resulted in similar success rate with a faster procedure time when compared with nerve stimulator, thus providing a possible effect on resident education and operating room efficiency.
-
New laryngoscopes have become available for use in small children. The aim of the study was to compare the Storz® videolaryngoscope (SVL) to the Airtraq® Optical laryngoscope (AOL) for tracheal intubation in children younger than two years of age who had a normal airway assessment. Our hypothesis was that the SVL would have a better success rate than the AOL. ⋯ No difference in the success rate of endotracheal intubation could be established in this ten patient sample of children younger than two years with a normal airway assessment scheduled for elective cleft lip/palate surgery. However, the Airtraq® Optical videolaryngoscope showed a number of time related advantages over the Storz® videolaryngoscope. Because of the small sample size a larger trial is needed to confirm these findings. Both devices were considered safe in all intubations.
-
⋯ If simple maneuvers of ventilation or anesthetic technique can prevent cerebral hypoxia, patient outcome may be improved. This is the first study to investigate the effects of ventilation strategies on cerebral oxygenation in patients anesthetized in beach chair position.
-
Interscalene block (ISB) is commonly performed using 20-40 mL of local anesthetic. Spread to adjacent structures and consequent adverse effects including paralysis of the ipsilateral hemidiaphragm are frequent. Pain ratings, analgesic requirements, adverse events, satisfaction, function and diaphragmatic excursion were compared following interscalene block (ISB) with reduced initial bolus volumes. ⋯ ISB provided reliable surgical analgesia with 5 mL, 10 mL or 20 mL ropivacaine (0.75%). The 20 mL volume was associated with increased complaints of dyspnea. The 5 mL volume was associated with statistically higher pain scores in the immediate postoperative period. Lower volumes resulted in a reduced incidence of dyspnea compared to 20 mL, however diaphragmatic impairment was not eliminated. Compensatory increases in contralateral diaphragmatic movement may explain tolerance for ipsilateral paresis.
-
The i-gel™, LMA-Supreme (LMA-S) and Laryngeal Tube Suction-D (LTS-D) are single-use supraglottic airway devices with an inbuilt drainage channel. We compared them with regard to their position in situ as well as to clinical performance data during elective surgery. ⋯ All devices were suitable for ventilating the patients' lungs during elective surgery.