Anesthesiology research and practice
-
A continuous peripheral nerve block (cPNB) is provided in the hospital and ambulatory setting. The most common use of CPNBs is in the peri- and postoperative period but different indications have been described like the treatment of chronic pain such as cancer-induced pain, complex regional pain syndrome or phantom limb pain. ⋯ Unfortunately, there are only few data demonstrating benefits after catheter removal and the evidence of medium- or long-term improvements in health-related quality of life measures is still lacking. This review will give an overview of the advantages and adverse effects of cPNBs.
-
Anesthesiol Res Pract · Jan 2012
Clinical implications of the transversus abdominis plane block in adults.
The transversus abdominis plane (TAP) block is a relatively new regional anesthesia technique that provides analgesia to the parietal peritoneum as well as the skin and muscles of the anterior abdominal wall. It has a high margin of safety and is technically simple to perform, especially under ultrasound guidance. ⋯ In part, this may be related to the limited sources for anesthesiologists to develop an appreciation for its sound anatomical basis and the versatility of its clinical application. As such, we provide a brief historical perspective on the TAP block, describe relevant anatomy, review current techniques, discuss pharmacologic considerations, and summarize the existing literature regarding its clinical utility with an emphasis on recently published studies that have not been included in other systematic reviews or meta-analyses.
-
Anesthesiol Res Pract · Jan 2012
Dexmedetomidine versus Remifentanil for Sedation during Awake Fiberoptic Intubation.
This study compared remifentanil and dexmedetomidine as awake fiberoptic intubation (AFOI) anesthetics. Thirty-four adult ASA I-III patients were enrolled in a double-blinded randomized pilot study to receive remifentanil (REM) or dexmedetomidine (DEX) for sedation during AFOI (nasal and oral). Thirty patients completed the study and received 2 mg midazolam IV and topical anesthesia. ⋯ Postloading dose verbal recall was poorer in the DEX group. Dexmedetomidine seems a useful adjunct for patients undergoing AFOI but is dependent on dosage and time. Further studies in the use of dexmedetomidine for AFOI are warranted.
-
Anesthesiol Res Pract · Jan 2012
Evaluation of fluid responsiveness: is photoplethysmography a noninvasive alternative?
Background. Goal-directed fluid therapy reduces morbidity and mortality in various clinical settings. Respiratory variations in photoplethysmography are proposed as a noninvasive alternative to predict fluid responsiveness during mechanical ventilation. ⋯ Conclusion. Although photoplethysmography is a promising technique, predictive values and correlations with other hemodynamic variables indicating fluid responsiveness vary substantially. Presently, it is not documented that photoplethysmography is adequately valid and reliable to be included in clinical practice for evaluation of fluid responsiveness.
-
Anesthesiol Res Pract · Jan 2012
Randomised Comparison of the AMBU AuraOnce Laryngeal Mask and the LMA Unique Laryngeal Mask Airway in Spontaneously Breathing Adults.
We conducted a randomised single-blind controlled trial comparing the LMA-Unique (LMAU) and the AMBU AuraOnce (AMBU) disposable laryngeal mask in spontaneously breathing adult patients undergoing general anaesthesia. Eighty-two adult patients (ASA status I-IV) were randomly allocated to receive the LMAU or AMBU and were blinded to device selection. Patients received a standardized anesthetic and all airway devices were inserted by trained anaesthetists. ⋯ When compared with the LMAU, the AMBU produced significantly higher airway sealing pressures (AMBU 20 ± 6; LMAU 15 ± 7 cm H(2)O; P = 0.001). There was no statistical difference between the two devices for overall success rate, insertion time, number of adjustments, laryngeal alignment, blood-staining, and sore throat (P ≥ 0.05). The AMBU AuraOnce disposable laryngeal mask provided a higher oropharyngeal leak pressure compared to the LMA Unique in spontaneously breathing adult patients.