Anesthesiology research and practice
-
Anesthesiol Res Pract · Jan 2015
Survey of Accepted Practice following Failed Intubation for Emergency Caesarean Delivery.
Background. There is no consensus on the optimum management of failed tracheal intubation in emergency cesarean delivery performed for fetal compromise. The decision making process on whether to wake the patient or continue anesthesia with a supraglottic airway device is an underexplored area. ⋯ Preoperative patient consent regarding the use of a supraglottic airway device for surgery in the event of failed intubation would affect the decision making of 40% of anaesthetists surveyed. Conclusion. These results demonstrate that a significant body of anesthetists with a subspecialty interest in obstetric anesthesia in the UK would not always wake up the patient and would continue with anesthesia and surgery with a supraglottic airway device in this setting.
-
Anesthesiol Res Pract · Jan 2015
Influence of Head and Neck Position on Oropharyngeal Leak Pressure and Cuff Position with the ProSeal Laryngeal Mask Airway and the I-Gel: A Randomized Clinical Trial.
Background. This study was designed to assess and compare the effect of head and neck position on the oropharyngeal leak pressures and cuff position (employing fibreoptic view of the glottis) and ventilation scores between ProSeal LMA and the I-gel. Material and Methods. ⋯ Effective ventilation can be done with both ProSeal LMA and I-gel with head in all the above positions. ProSeal LMA has a better margin of safety than I-gel due to better sealing pressures except in flexion where the increase in airway pressure is more with the former. Extreme precaution should be taken in flexion position in ProSeal LMA.
-
Anesthesiol Res Pract · Jan 2015
Evaluation of Waste Anesthetic Gas in the Postanesthesia Care Unit within the Patient Breathing Zone.
Potential health hazards from waste anesthetic gases (WAGs) have been a concern since the introduction of inhalational anesthetics into clinical practice. The potential to exceed recommended exposure levels (RELs) in the postanesthesia care unit (PACU) exists. The aim of this pilot study was to assess sevoflurane WAG levels while accounting for factors that affect inhalational anesthetic elimination. ⋯ Further analysis suggests that the rate of washout of sevoflurane was dependent on the duration of anesthetic exposure. This study demonstrated that clinically relevant inhalational anesthetic concentrations result in sevoflurane WAG levels that exceed current RELs. Evaluating peak and cumulative sevoflurane WAG levels in the breathing zone of PACU Phase I and Phase II providers is warranted to quantify the extent and duration of exposure.
-
Anesthesiol Res Pract · Jan 2015
Comparison of the Disposable Streamlined Liner of the Pharynx Airway and the Disposable I-gel in Anaesthetized, Paralyzed Adults: A Randomized Prospective Study.
Introduction. This study compared streamlined liner of the pharynx airway (SLIPA) and I-gel noninflatable, single-use, supraglottic airway device (SAD) performance in anesthetized, paralyzed adults. Methods. ⋯ The SLIPA provided better airway sealing pressure. Both devices had similar mechanical ventilation and oxygenation characteristics and comparable hemodynamic stability. Both noninflatable SADs are useful, but SLIPA rapid insertion and good airway sealing make it an effective alternative to the I-gel.