Physics in medicine and biology
-
As an alternative to the use of traditional parallel hole collimators, SPECT imaging can be performed using rotating slat collimators. While maintaining the spatial resolution, a gain in image quality could be expected from the higher photon collection efficiency of this type of collimator. However, the use of iterative methods to do fully three-dimensional (3D) reconstruction is computationally much more expensive and furthermore involves slow convergence compared to a classical SPECT reconstruction. ⋯ Calculation of computational load and convergence for the different algorithms shows a speedup for the new method of 38 and 426 compared to the split matrix MLEM approach and the fully 3D MLEM respectively and a speedup of 16 and 21 compared to the split matrix OSEM and the fully 3D OSEM respectively. A contrast-to-noise study based on simulated data shows that our new approach has comparable accuracy as the fully 3D reconstruction method. The algorithm developed in this study allows iterative image reconstruction of rotating slat collimated SPECT data with equal image quality in a comparable amount of computation time as a classical SPECT reconstruction.
-
In this study we present two prediction methods, mean dose and summed dose, for predicting the number of A549 cells that will survive after modulated x-ray irradiation. The prediction methods incorporate the dose profile from the modulated x-ray fluence map applied across the cell sample and the linear quadratic (LQ) model. We investigated the clonogenic survival of A549 cells when irradiated using two different modulated x-ray fluence maps. ⋯ The change in the cell survival for the unirradiated regions of the two different dose gradients may be an important factor to consider when predicting the number of cells that will survive at the edge of modulated x-ray fields. This investigation provides an improved method of predicting cell survival for modulated x-ray radiation treatment. It highlights the limitations of the LQ model, particularly in its ability to describe the biological response of cells irradiated under these conditions.
-
As a clinical application of an exciting scientific breakthrough, a compact and cost-efficient proton therapy unit using high-power laser acceleration is being developed at Fox Chase Cancer Center. The significance of this application depends on whether or not it can yield dosimetric superiority over intensity-modulated radiation therapy (IMRT). The goal of this study is to show how laser-accelerated proton beams with broad energy spreads can be optimally used for proton therapy including intensity-modulated proton therapy (IMPT) and achieve dosimetric superiority over IMRT for prostate cancer. ⋯ IMPT can also reduce the whole body non-target tissue dose by up to 61% or a factor 2.5. This study has shown that the laser accelerator under development has a potential to generate high-quality proton beams for cancer treatment. Significant improvement in target dose uniformity and normal tissue sparing as well as in reduction of whole body dose can be achieved by IMPT with appropriate optimization and beam setup.
-
Currently, there are two types of treatment planning algorithms for intensity modulated radiation therapy (IMRT). The beamlet-based algorithm generates beamlet intensity maps with high complexity, resulting in large numbers of segments in the delivery after a leaf-sequencing algorithm is applied. The segment-based direct aperture optimization (DAO) algorithm includes the physical constraints of the deliverable apertures in the calculation, and achieves a conformal dose distribution using a small number of segments. ⋯ Under the condition that the clinical acceptance criteria of the treatment plan are satisfied, for the prostate patient, the total number of segments for five fields is reduced from 61 using the Eclipse planning system to 35 using the proposed algorithm; for the head and neck patient, the total number of segments for seven fields is reduced from 107 to 28. The head and neck result is also compared to that using an equal number of four segments for each field. The comparison shows that using field-specific numbers of segments achieves a much improved dose distribution.
-
The development and evaluation of a prototype cardiac gating system for double-shot dual-energy (DE) imaging is described. By acquiring both low- and high-kVp images during the resting phase of the cardiac cycle (diastole), heart misalignment between images can be reduced, thereby decreasing the magnitude of cardiac motion artifacts. For this initial implementation, a fingertip pulse oximeter was employed to measure the peripheral pulse waveform ('plethysmogram'), offering potential logistic, cost and workflow advantages compared to an electrocardiogram. ⋯ To quantify the effect of the gating system on DE image quality, human observer tests were conducted to measure the magnitude of cardiac artifact under conditions of successful and unsuccessful diastolic gating. Six observers independently measured the artifact in 111 patient DE images. The data indicate that successful diastolic gating results in a statistically significant reduction (p < 0.001) in the magnitude of cardiac motion artifact, with residual artifact attributed primarily to gross patient motion.