Journal of clinical monitoring
-
The pulmonary elimination of the volume of CO2 per breath (VCO2/br, integration of product of airway flow (V) and PCO2 over a single breath) is a sensitive monitor of cardio-pulmonary function and tissue metabolism. Negligible inspired PCO2 results when the capnometry sampling site (SS) is positioned at the entry of the inspiratory limb to the airway circuit. In this study, we test the hypothesis that moving SS lungward will result in significant inspired CO2 (VCO2[I]), that needs to be excluded from VCO2/br. ⋯ When the SS was moved lungward from the inspiratory limb, instrumental dead space (VDINSTR) increased and, at end-expiration, contained exhaled CO2 from the previous breath. During the next inspiration, this CO2 was rebreathed relative to SS (i.e. VCO2[I]), and contributed to VCO2[E]. Thus, VCO2[E] overestimated VCO2/br (%error) by the amount of rebreathing, which was exacerbated by larger VDINSTR (increased VCO2[I]) or smaller VT (increased VCO2[I]-to-VCO2/br ratio).
-
Comparative Study
EEG Predicts movement response to surgical stimuli during general anesthesia with combinations of isoflurane, 70% N2O, and fentanyl.
Our objective was to evaluate the performance of the EEG as an indicator of anesthetic depth by measuring EEG prediction of movement response to surgical stimuli. ⋯ The EEG, expressed as F95, predicted movement response to surgical stimuli during combinations of isoflurane, 70% N2O, and fentanyl. The F95-response curves shifted upward on the frequency scale for the less intense stimuli and for anesthetic techniques using 70% N2O, fentanyl, or both. F95 prediction of movement response appeared to be related to anesthetic agent doses. Our F95-response curves may provide helpful guidelines for using F95 to titrate the administration of anesthetic agents and for assessing the depth of general anesthesia.
-
Comparative Study
Equivalence of fast flush and square wave testing of blood pressure monitoring systems.
The accurate recording of intraarterial pressure depends upon an appropriate dynamic response of the monitoring system. Generation of a square wave (SW) at the catheter tip is the engineering and in vitro laboratory gold standard. Fast flush (FF) testing is the clinical test of choice. Results from these two test methods have been assumed equal but have not been empirically confirmed. ⋯ For the characterization of dynamic response of invasive blood pressure monitoring systems, the FF test and SW test yield identical results. However, under certain conditions-air, R.O.S.E device-dynamic response as measured by FF testing was not equivalent to dynamic response as measured by the gold standard-the SW test. Specifically, small amounts of air in fluid-filled invasive blood pressure monitoring systems cause a slightly worse dynamic response as measured by FF testing versus the laboratory gold standard-the SW test.
-
To compare values measured by a continuous intra-arterial blood gas monitoring system with those measured by conventional blood gas analyzer for the assessment of the clinical performance of a new device for measurement of PaO2, PaCO2, and arterial pH. ⋯ The PO2 and pH values derived from an intra-arterial blood gas monitoring system agreed well with the values measured by a conventional blood gas analyzer. However, the PCO2 value must be corrected due to an increase of drift, especially with extended use for more than 72 hours.
-
The Ultima SV respiratory monitor can be used to monitor the intraoperative effects of the lateral decubitus position and one-lung ventilation on ventilatory mechanics. ⋯ One-lung ventilation caused several changes in the whole respiratory system (lung, thorax, and endotracheal tube). Continuous monitoring of flow-rate-volume or pressure-volume loops with in-line spirometry provided comprehensive information regarding parameters in one-lung ventilation.