Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference
-
Conf Proc IEEE Eng Med Biol Soc · Jan 2013
Effect of hypothermia on cortical and thalamic signals in anesthetized rats.
Beneficial effects of hypothermia on subjects with neuro-pathologies have been well demonstrated in both animal studies and clinical trials. Although it is known that temperature significantly impacts neurological injuries, the underlying mechanism remains unclear. We studied the effect of temperature modulation on neural signals in the cortex and the thalamus in uninjured brains of anesthetized rats. ⋯ In addition, our results showed that hypothermia significantly increased the burst suppression ratio (BSR) in EEG, cortical and thalamic signals by 3.42, 3.25, 7.29 times respectively (P<0.01), and prolonged the latency of neuronal response in cortex to median nerve stimulation from 9 ms to 16 ms (P<0.01). Furthermore, during normothermia, the correlation coefficient between thalamic and cortical signals was 0.35±0.02 while during hypothermia, it decreased to 0.16±0.03 with statistical significance (P<0.01). These results can potentially assist in better understanding the effects of hypothermia.
-
Conf Proc IEEE Eng Med Biol Soc · Jan 2013
Peristaltic hemodynamics of a new pediatric circulatory assist system for Fontan circulation using shape memory alloy fibers.
Fontan procedure is one of the common surgical treatments of congenital heart diseases. Patients with Fontan circulation have single ventricle in the systemic circulation with the total cavopulmonary connection. We have been developing a pulmonary circulatory assist device using shape memory alloy fibers for Fontan circulation with total cavopulmonary connection. ⋯ Then, we developed a sequential contraction controller for the assist system, which could reproduce the wall contractile velocity at 6.0 to 20.0 cm/sec. We examined hemodynamic characteristic of its function using a mock circulatory system, which consisted of two overflow tanks representing venous and pulmonary arterial pressures in Fontan circulation. As a result, the pulmonary circulation assist device with sequential contraction could achieve effective promotion of the pulsatility in pulmonary arterial flow.
-
Conf Proc IEEE Eng Med Biol Soc · Jan 2013
Hypnosis control based on the minimum concentration of anesthetic drug for maintaining appropriate hypnosis.
This paper proposes a novel hypnosis control method using Auditory Evoked Potential Index (aepEX) as a hypnosis index. In order to avoid side effects of an anesthetic drug, it is desirable to reduce the amount of an anesthetic drug during surgery. For this purpose many studies of hypnosis control systems have been done. ⋯ The minimum effect-site concentration is estimated utilizing the property of aepEX pharmacodynamics. The infusion rate of propofol is adjusted so that effect-site concentration of propofol may be kept near and always above the minimum effect-site concentration. Simulation results of hypnosis control using the proposed method show that the minimum concentration can be estimated appropriately and that the proposed control method can maintain hypnosis adequately and reduce the total infusion amount of propofol.
-
Conf Proc IEEE Eng Med Biol Soc · Jan 2013
Pilot investigation of anterior fontanelle photoplethysmographic signals and their suitability in estimating arterial oxygen saturation.
There is a need for more reliable, non-invasive and alternative measurement sites for the monitoring of arterial blood oxygen saturation in critically ill newborns at times of peripheral compromise. A pilot investigation on 14 Intensive Care Unit (ICU) newborns was conducted utilizing custom-made reflectance photoplethysmographic (PPG) sensors placed at the fontanelle and foot. The results suggest that the fontanelle is sensitive to changes in saturation, where saturation values obtained from the custom sensor were compared against commercial pulse oximeter values and results from a blood gas analyzer, however careful placement of the sensor at the fontanelle is an issue that needs further investigation.
-
Depth of anesthesia can be indirectly measured by Bispectral Index (BIS), therefore it is possible to administer propofol in a closed loop to maintain the optimal level of anesthesia while minimizing the dose to improve the postanesthesia recovery. High-Order Sliding-Mode control can be used to individualize drug dosing. In this study, the controller is tested with four in silico patients.