BMC emergency medicine
-
BMC emergency medicine · Jan 2009
Randomized Controlled Trial Comparative StudyComparison of the Glidescope and Pentax AWS laryngoscopes to the Macintosh laryngoscope for use by advanced paramedics in easy and simulated difficult intubation.
Intubation of the trachea in the pre-hospital setting may be lifesaving in severely ill and injured patients. However, tracheal intubation is frequently difficult to perform in this challenging environment, is associated with a lower success rate, and failed tracheal intubation constitutes an important cause of morbidity. Novel indirect laryngoscopes, such as the Glidescope and the AWS laryngoscopes may reduce this risk. ⋯ The Glidescope and AWS devices possess advantages over the conventional Macintosh laryngoscope when used by Advanced Paramedics in normal and simulated difficult intubation scenarios in this manikin study. Further studies are required to extend these findings to the clinical setting.
-
BMC emergency medicine · Jan 2008
Randomized Controlled Trial Multicenter StudyAn evaluation of a Shockroom located CT scanner: a randomized study of early assessment by CT scanning in trauma patients in the bi-located trauma center North-West Netherlands (REACT trial).
Trauma is a major source of morbidity and mortality, especially in people below the age of 50 years. For the evaluation of trauma patients CT scanning has gained wide acceptance in and provides detailed information on location and severity of injuries. However, CT scanning is frequently time consuming due to logistical (location of CT scanner elsewhere in the hospital) and technical issues. An innovative and unique infrastructural change has been made in the AMC in which the CT scanner is transported to the patient instead of the patient to the CT scanner. As a consequence, early shockroom CT scanning provides an all-inclusive multifocal diagnostic modality that can detect (potentially life-threatening) injuries in an earlier stage, so that therapy can be directed based on these findings. ⋯ The REACT-trial will provide evidence on the effects of a strategy involving early shockroom CT scanning compared with a standard diagnostic imaging strategy in trauma patients on both patient outcome and operations research.
-
BMC emergency medicine · Jan 2008
Randomized Controlled TrialInfluence of airway management strategy on "no-flow-time" during an "advanced life support course" for intensive care nurses - a single rescuer resuscitation manikin study.
In 1999, the laryngeal tube (VBM Medizintechnik, Sulz, Germany) was introduced as a new supraglottic airway. It was designed to allow either spontaneous breathing or controlled ventilation during anaesthesia; additionally it may serve as an alternative to endotracheal intubation, or bag-mask ventilation during resuscitation. Several variations of this supraglottic airway exist. In our study, we compared ventilation with the laryngeal tube suction for single use (LTS-D) and a bag-mask device. One of the main points of the revised ERC 2005 guidelines is a low no-flow-time (NFT). The NFT is defined as the time during which no chest compression occurs. Traditionally during the first few minutes of resuscitation NFT is very high. We evaluated the hypothesis that utilization of the LTS-D could reduce the NFT compared to bag-mask ventilation (BMV) during simulated cardiac arrest in a single rescuer manikin study. ⋯ In our manikin study, NFT was reduced significantly when using LTS-D compared to BMV. During cardiac arrest, the LTS-D might be a good alternative to BMV for providing and maintaining a patent airway. For personnel not experienced in endotracheal intubation it seems to be a safe airway device in a manikin use.