Frontiers in medicine
-
Frontiers in medicine · Jan 2021
Measuring Core Body Temperature Using a Non-invasive, Disposable Double-Sensor During Targeted Temperature Management in Post-cardiac Arrest Patients.
Background: Precisely measuring the core body temperature during targeted temperature management after return of spontaneous circulation is mandatory, as deviations from the recommended temperature might result in side effects such as electrolyte imbalances or infections. However, previous methods are invasive and lack easy handling. A disposable, non-invasive temperature sensor using the heat flux approach (Double Sensor), was tested against the standard method: an esophagus thermometer. ⋯ Influences on the measurements of the Double Sensor by drugs administered could also be ruled out. Conclusions: This study could demonstrate that measuring the core body temperature with the non-invasive, disposable sensor shows excellent reliability during targeted temperature management after survived cardiac arrest. Nonetheless, clinical research concerning the implementation of the sensor in other fields of application should be supported, as well as verifying our results by a larger patient cohort to possibly improve the limits of agreement.
-
Frontiers in medicine · Jan 2021
The Risk of Neuraxial Anesthesia-Related Hypotension in COVID-19 Parturients Undergoing Cesarean Delivery: A Multicenter, Retrospective, Propensity Score Matched Cohort Study.
Background: SARS-CoV-2 infection was referred to sympathetic hyperactivity, which might increase the susceptibility of neuraxial anesthesia-related hypotension resulted from sympathetic inhibition. We conducted a multicenter, retrospective, propensity score matched (PSM) cohort study to determine whether COVID-19 parturients have an increased risk of hypotension after neuraxial anesthesia for cesarean delivery. Methods: Clinical data of COVID-19 parturients were collected from the electronic medical records from 1th January to 31th May, 2020 in three hospitals of Hubei Province, China. ⋯ The incidences of nausea, vomiting, dizziness, and shaking were significantly higher in the COVID-19 group than Control group (48.5 vs. 17.2%, P < 0.001; 10.9 vs. 4.3%, P = 0.03; 18.8 vs. 3.2%, P < 0.001; 51.5 vs. 18.3%, P < 0.001; respectively). The Apgar scores at 1 min was significantly lower in newborns from COVID-19 parturients than that in Control babies (P = 0.04). Conclusions: An increased risk of neuraxial anesthesia-related hypotension in COVID-19 parturients undergoing cesarean delivery should be stressed.
-
Frontiers in medicine · Jan 2021
Useful Ultrasonographic Parameters to Predict Difficult Laryngoscopy and Difficult Tracheal Intubation-A Systematic Review and Meta-Analysis.
Unexpected difficult airway management can cause significant morbidity and mortality in patients admitted for elective procedures. Ultrasonography is a promising tool for perioperative airway assessment, nevertheless it is still unclear which sonographic parameters are useful predictors of difficult laryngoscopy and tracheal intubation. To determine the ultrasonographic predictors of a difficult airway that could be applied for routine practice, a systematic review and meta-analysis was conducted. ⋯ The overall effect of the distance from skin to hyoid bone (p = 0.02); skin to epiglottis (p = 0.02); skin to the anterior commissure of vocal cords (p = 0.02), pre-epiglottis space to distance between epiglottis and midpoint between vocal cords (p = 0.01), hyomental distance in neutral (p < 0.0001), and extended (p = 0.0002) positions and ratio of hyomental distance in neutral to extended (p = 0.001) was significant. This study shows that hyomental distance in the neutral position is the most reliable parameter for pre-operative airway ultrasound assessment. The main limitations of the study are the small sample size, heterogeneity of studies, and absence of a standardized ultrasonographic evaluation method [Registered at International prospective register of systematic reviews (PROSPERO): number 167931].
-
Frontiers in medicine · Jan 2021
Identifying Clinical Phenotypes in Moderate to Severe Acute Respiratory Distress Syndrome Related to COVID-19: The COVADIS Study.
Objectives: Different phenotypes have been identified in acute respiratory distress syndrome (ARDS). Existence of several phenotypes in coronavirus disease (COVID-19) related acute respiratory distress syndrome is unknown. We sought to identify different phenotypes of patients with moderate to severe ARDS related to COVID-19. ⋯ Conclusions: In COVID-19 patients with moderate to severe ARDS, we identified three clinical phenotypes. One of these included older people with comorbidities who had a fulminant course of disease with poor prognosis. Requirement of different treatments and ventilatory strategies for each phenotype needs further investigation.
-
Frontiers in medicine · Jan 2021
Measurement of the Total Lung Volume Using an Adjusted Single-Breath Helium Dilution Method in Patients With Obstructive Lung Disease.
Background: Whole-body plethysmography (WBP) is the gold standard for measuring lung volume, but its clinical application is limited as it requires expensive equipment and is not simple to use. Studies have shown that the single-breath helium dilution (SBHD) method, which is commonly used in clinical practice, significantly underestimates lung volume in patients with obstructive lung disease (OLD). By comparing the differences in lung volume measured using SBHD and WBP, we aimed to establish a correction equation for the SBHD method to determine the total lung volume in patients with OLD of different severities. ⋯ With the correction equation, no statistical difference was observed between TLC (adjusted SBHD) and TLC (WBP) among the obstruction degree groups (P > 0.05). Conclusions: The SBHD method is correlated with WBP to measure the total lung volume, but the SBHD method presents limitations in determining the total lung volume in patients with obstructive lung disease. Here, we established an effective and reliable correction equation in order to accurately assess the total lung volume of patients with OLD using the SBHD method.