Emergency medicine journal : EMJ
-
Observational Study
Validation of the five-tier Taiwan Triage and Acuity Scale for prehospital use by Emergency Medical Technicians.
This study aimed to determine the inter-rater reliability of the five-level Taiwan Triage and Acuity Scale (TTAS) when used by emergency medical technicians (EMTs) and triage registered nurses (TRNs). Furthermore, it sought to validate the prehospital TTAS scores according to ED hospitalisation rates and medical resource consumption. ⋯ A five-level prehospital triage scale shows good inter-rater reliability and superior discrimination compared with the two-level system for prediction of hospitalisation and medical resource requirements.
-
Capillary refill (CR) time is traditionally assessed by 'naked-eye' inspection of the return to original colour of a tissue after blanching pressure. Few studies have addressed intra-observer reliability or used objective quantification techniques to assess time to original colour. This study compares naked-eye assessment with quantified CR (qCR) time using polarisation spectroscopy and examines intra-observer and interobserver agreements in using the naked eye. ⋯ Our study suggests that naked-eye-assessed CR time shows poor reproducibility, even by the same observers, and differs from an objective measure of CR time.
-
Editorial
Recognising bias in studies of diagnostic tests part 2: interpreting and verifying the index test.
Multiple pitfalls can occur with the conduct and analysis of a study of diagnostic tests, resulting in biased accuracy. Our conceptual model includes three stages: patient selection, interpretation of the index test and disease verification. ⋯ However, there are circumstances when certain choices in study design are unavoidable, and result in biased test characteristics. In this case, the informed reader will better judge the quality of a study by recognising the potential biases and limitations by being methodical in their approach to understanding the methods, and in turn, better apply studies of diagnostic tests into their clinical practice.
-
Recent terror attacks and assassinations involving highly toxic chemical weapons have stressed the importance of sufficient respiratory protection of medical first responders and receivers. As full-face respirators cause perceptual-motor impairment, they not only impair vision but also significantly reduce speech intelligibility. The recent introduction of electronic voice projection units (VPUs), attached to a respirator, may improve communication while wearing personal respiratory protection. ⋯ We found that the Avon C50 is the preferred model among the tested respirators. In our model, electronic voice projection modules improved loudness but not speech intelligibility. The Respirex PRPS NHS-suit was rated significantly less favourably in respect of medical communication and speech intelligibility.