Emergency medicine journal : EMJ
-
Observational Study
Paediatric acute non-traumatic limp presenting to the emergency department: a retrospective observational study.
Acute non-traumatic limp in children has many causes, ranging from common benign and self-limiting disease to serious time-sensitive emergencies such as septic arthritis. We aimed to (1) describe the epidemiology and workup of paediatric acute non-traumatic limp presentation in three Australian EDs and (2) compare investigations and treatment between a tertiary paediatric centre and two non-tertiary centres. ⋯ Although mostly due to benign disorders, an important number of limping children who presented to the ED had serious disease, with approximately one-third of these not diagnosed at the initial ED visit. There is large variation in workup including blood test, imaging and decisions regarding ED disposition.
-
Prehospital neuroprotective strategies aim to prevent secondary insults (SIs) in traumatic brain injury (TBI). This includes haemodynamic optimisation in addition to oxygenation and ventilation targets achieved through rapid sequence intubation (RSI).The primary aim was to report the incidence and prevalence of SIs (prolonged hypotension, prolonged hypoxia and hyperventilation) and outcomes of patients with TBI who were intubated in the prehospital setting. ⋯ SIs were common in the early phase of prehospital care. The association of prolonged hypoxia and mortality in TBI is potentially more significant than previously recognised, and if corrected early, may improve outcomes. There may be a greater role for bystander intervention in prevention of early hypoxic insult in TBI.
-
Observational Study
Inverse association between blood pressure and pulse oximetry accuracy: an observational study in patients with suspected or confirmed COVID-19 infection.
Pulse oximeters are a standard non-invasive tool to measure blood oxygen levels, and are used in multiple healthcare settings. It is important to understand the factors affecting their accuracy to be able to use them optimally and safely. This analysis aimed to explore the association of the measurement error of pulse oximeters with systolic BP, diastolic BP and heart rate (HR) within ranges of values commonly observed in clinical practice. ⋯ Care needs to be taken in interpreting pulse oximetry measurements in patients with lower systolic and diastolic BPs, and HRs, as oxygen saturation is overestimated as BP and HR decrease. Confirmation of the oxygen saturation with an ABG may be appropriate in some clinical scenarios.
-
COVID-19 symptoms vary widely. This retrospective study assessed which of three clinical screening tools-a nursing triage screen (NTS), an ED review of systems (ROS) performed by physicians and physician assistants and a standardised ED attending (ie, consultant) physician COVID-19 probability assessment (PA)-best identified patients with COVID-19 on a subsequent reverse transcription PCR (RT-PCR) confirmation. ⋯ The ED attending PA had higher sensitivity and specificity than the other two methods, but none was accurate enough to replace a COVID-19 RT-PCR test in a clinical setting where transmission control is crucial. Therefore, we recommend universal COVID-19 testing prior to all admissions.