• Medicine · Aug 2020

    Comparative Study Observational Study

    Usefulness of an additional lead shielding device in reducing occupational radiation exposure during interventional endoscopic procedures: An observational study.

    • Reiko Yamada, Yusuke Saimyo, Kyosuke Tanaka, Aiji Hattori, Yuhei Umeda, Naoki Kuroda, Junya Tsuboi, Yasuhiko Hamada, and Yoshiyuki Takei.
    • Department of Gastroenterology and Hepatology.
    • Medicine (Baltimore). 2020 Aug 21; 99 (34): e21831.

    AbstractAdoption of interventional endoscopic procedures is increasing with increasing prevalence of diseases. However, medical radiation exposure is concerning; therefore, radiation protection for medical staff is important. However, there is limited information on the usefulness of an additional lead shielding device during interventional endoscopic procedures. Therefore, we aimed to determine whether an additional lead shielding device protects medical staff from radiation.An X-ray unit (CUREVISTA; Hitachi Medical Systems, Tokyo, Japan) with an over-couch X-ray system was used. Fluoroscopy-associated scattered radiation was measured using a water phantom placed at the locations of the endoscopist, assistant, nurse, and clinical engineer. For each location, measurements were performed at the gonad and thyroid gland/eye levels. Comparisons were performed between with and without the additional lead shielding device and with and without a gap in the shielding device. Additionally, a clinical study was performed with 27 endoscopic retrograde cholangiopancreatography procedures.The scattered radiation dose was lower with than without additional lead shielding at all medical staff locations and decreased by 84.7%, 82.8%, 78.2%, and 83.7%, respectively, at the gonad level and by 89.2%, 86.4%, 91.2%, and 87.0%, respectively, at the thyroid gland/eye level. Additionally, the scattered radiation dose was lower without than with a gap in the shielding device at all locations.An additional lead shielding device could protect medical staff from radiation during interventional endoscopic procedures. However, gaps in protective equipment reduce effectiveness and should be eliminated.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?

    User can't be blank.

    Content can't be blank.

    Content is too short (minimum is 15 characters).

    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.