• JAMA · Aug 2015

    Characteristics of Clinical Studies Conducted Over the Total Product Life Cycle of High-Risk Therapeutic Medical Devices Receiving FDA Premarket Approval in 2010 and 2011.

    • Vinay K Rathi, Harlan M Krumholz, Frederick A Masoudi, and Joseph S Ross.
    • Yale University School of Medicine, New Haven, Connecticut2Center for Outcomes Research and Evaluation, Yale-New Haven Hospital, New Haven, Connecticut.
    • JAMA. 2015 Aug 11;314(6):604-12.

    ImportanceThe US Food and Drug Administration (FDA) approves high-risk medical devices, those that support or sustain human life or present potential unreasonable risk to patients, via the Premarket Approval (PMA) pathway. The generation of clinical evidence to understand device safety and effectiveness is shifting from predominantly premarket to continual study throughout the total product life cycle.ObjectiveTo characterize the clinical evidence generated for high-risk therapeutic devices over the total product life cycle.Design And SettingAll clinical studies of high-risk therapeutic devices receiving initial market approval via the PMA pathway in 2010 and 2011 identified through ClinicalTrials.gov and publicly available FDA documents as of October 2014.Main Outcomes And MeasuresStudies were characterized by type (pivotal, studies that served as the basis of FDA approval; FDA-required postapproval studies [PAS]; or manufacturer/investigator-initiated); premarket or postmarket; status (completed, ongoing, or terminated/unknown); and design features, including enrollment, comparator, and longest duration of primary effectiveness end point follow-up.ResultsIn 2010 and 2011, 28 high-risk therapeutic devices received initial marketing approval via the PMA pathway. We identified 286 clinical studies of these devices: 82 (28.7%) premarket and 204 (71.3%) postmarket, among which there were 52 (18.2%) nonpivotal premarket studies, 30 (10.5%) pivotal premarket studies, 33 (11.5%) FDA-required PAS, and 171 (59.8%) manufacturer/investigator-initiated postmarket studies. Six of 33 (18.2%) PAS and 20 of 171 (11.7%) manufacturer/investigator-initiated postmarket studies were reported as completed. No postmarket studies were identified for 5 (17.9%) devices; 3 or fewer were identified for 13 (46.4%) devices overall. Median enrollment was 65 patients (interquartile range [IQR], 25-111), 241 patients (IQR, 147-415), 222 patients (IQR, 119-640), and 250 patients (IQR, 60-800) for nonpivotal premarket, pivotal, FDA-required PAS, and manufacturer/investigator-initiated postmarket studies, respectively. Approximately half of all studies used no comparator (pivotal: 13/30 [43.3%]; completed postmarket: 16/26 [61.5%]; ongoing postmarket: 70/153 [45.8%]). Median duration of primary effectiveness end point follow-up was 3.0 months (IQR, 3.0-12.0), 9.0 months (IQR, 0.3-12.0), and 12.0 months (IQR, 7.0-24.0) for pivotal, completed postmarket, and ongoing postmarket studies, respectively.Conclusions And RelevanceAmong high-risk therapeutic devices approved via the FDA PMA pathway, total product life cycle evidence generation varied in both the number and quality of premarket and postmarket studies, with approximately 13% of initiated postmarket studies completed between 3 and 5 years after FDA approval.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…