    Background And AimsProSeal laryngeal mask airway (PLMA) is an established device for airway management, while Air-Q Blocker (AQB) is a relatively new supraglottic device. The aim of this study is to compare AQB against PLMA in adults undergoing laparoscopic cholecystectomy under general anesthesia.Material And MethodsEighty-eight adult patients scheduled for laparoscopic cholecystectomy under general anesthesia were randomly allocated into two groups. A drain tube (gastric tube for PLMA and blocker tube for AQB) was inserted through the drain channel of the respective device. PLMA was inserted in Group P (n = 44) and AQB was inserted in Group A (n = 44) to secure the airway. The primary endpoint was airway seal pressure. Secondarily, we sought to compare overall insertion success, ease of insertion, hemodynamic effects after initial placement, ease of drain tube placement, and perioperative oropharyngolaryngeal morbidity between the devices.ResultsOropharyngeal seal pressures for AQB and PLMA were 31.5 ± 2.41 and 29.41 ± 2.14 cm H2O, respectively (P = 0.01). Insertion time was longer with AQB than PLMA, 25.59 ± 5.71 and 18.66 ± 3.15 seconds, respectively (P = 0.001). Ease and success rate of insertion was better with PLMA compared to AQB. Failure of device insertion was seen in 2 cases of Group A. Gastric distension was seen in 4 patients in Group A, requiring replacement with endotracheal tube in two patients. Ventilation was successful in all 44 patients with PLMA. Both the devices were comparable in providing a patent airway and adequate oxygenation during controlled ventilation. There was an increased trend of airway trauma and complications in the AQB group.ConclusionBoth PLMA and AQB show similar efficacy in maintaining ventilation and oxygenation, during laparoscopic surgery. However, proper positioning and functioning of the blocker tube of AQB is a limiting factor, and needs further evaluation.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.