Performance of three new-generation pulse oximeters during motion and low perfusion in volunteers.
- Hamsa B Ragaswamy, Kavitha Govindugari, and Laverne Estanol.
- Department of Anesthesiology, Long Beach Veterans Affairs Healthcare System, Long Beach, CA 90822, USA. nitinshahmd@gmail.com
- J Clin Anesth. 2012 Aug 1;24(5):385-91.
Study ObjectiveTo evaluate pulse oximeter performance during motion and induced low perfusion in volunteers.DesignProspective volunteer study.SettingDirect Observation unit.Subjects10 healthy adult volunteers.InterventionsTen volunteers were monitored with three different pulse oximeters while they underwent desaturation to about 75% oxygen saturation (SpO(2)) and performed machine-generated (MG) and volunteer-generated (VG) hand movements with the test hand, keeping the control hand stationary.MeasurementsSpO(2) and pulse rate readings from the motion (test) and stationary (control) hands were recorded as well as the number of times and the duration that the oximeters connected to the test hands did not report a reading. Sensitivity, specificity, performance index for SpO(2), and pulse rate (PR) were calculated for each pulse oximeter by comparing performance of the test hand with the control hand.Main ResultsDuring both MG and VG motion, the Masimo Radical had higher SpO(2) specificity (93% and 97%) than the Nellcor N-600 (67% and 77%) or the Datex-Ohmeda TruSat (83% and 82%). The Masimo Radical also had higher SpO(2) sensitivity (100% and 95%) than the Nellcor N-600 (65% and 50%) or the Datex-Ohmeda TruSat (20% and 15%) during both MG and VG motion. During MG motion, the Masimo Radical had the lowest PR failure rate (0%) compared with the Nellcor N-600 (22.2%) and Datex-Ohmeda TruSat (1.3%). However, during VG motion, the Masimo Radical had the lowest SpO(2) failure rate (0%) of the three devices (Nellcor N-600 16.4% and Datex-Ohmeda TruSat 1.7%). Both the Masimo Radical and the Datex-Ohmeda TruSat had lower PR failure rates (0% and 4.4%) than the Nellcor N-600 (33.9%). There were no significant differences in SpO(2) or PR performance index between the three devices.ConclusionsThe Masimo Radical had higher SpO(2) sensitivity and specificity than the Nellcor N-600 and Datex-Ohmeda TruSat during conditions of motion and induced low perfusion in this volunteer study.Published by Elsevier Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.