Reuse of pacemakers: comparison of short and long-term performance.
- Santiago Nava, José L Morales, Manlio F Márquez, Fausto Barrera, Jorge Gómez, Luis Colín, Josep Brugada, and Pedro Iturralde.
- Instituto Nacional de Cardiología "Ignacio Chávez, Department of Electrocardiology, Juan Badiano 1 Col Sección XVI, Tlalpan 14080, Mexico City, Mexico. santiagonavat@hotmail.com
- Circulation. 2013 Mar 19; 127 (11): 1177-83.
BackgroundIn developing economies, there are patients in whom pacemaker implantation is delayed because they cannot afford one. Reused devices have been a solution. To address concerns about safety, a cohort of consecutive patients implanted with a reused pacemaker was compared with a control group.Methods And ResultsA cohort of 603 consecutive patients from 2000 to 2010 was studied in an ambispective noninferiority study. The study group patients (n=307) received resterilized pacemakers, and the control group patients (n=296) received a new pacemaker. A combined end point of 3 major outcomes-unexpected battery depletion, infection, and device dysfunction-was analyzed. A total of 85 pacemakers had to be explanted, 31 in the control group (10.5%) and 54 in the study group (17.6%; relative risk, 1.68; 95% confidence interval, 1.1-2.5; P=0.02). Forty-three reached the primary end point, 16 in the control group (5.5%) and 27 in the study group (7.2%; relative risk, 1.3; 95% confidence interval, 0.70-2.45; P=0.794). In terms of individual outcomes, 5 new pacemakers (1.7%) and 11 resterilized pacemakers (3.6%) had unexpected battery depletion (relative risk, 2.12; 95% confidence interval, 0.75-6; P=0.116); 3.7% new pacemakers and 3.2% reused pacemakers had a procedure-related infection (relative risk, 0.87; 95% confidence interval, 0.38-2.03; P=0.46); and 1 pacemaker in the study group malfunctioned.ConclusionsPacemaker reuse is feasible and safe and is a viable option for patient with bradyarrhythmias. Other than the expected shorter battery life, reuse of pacemaker generators is not inferior to the use of new devices.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.