JACC Cardiovasc Interv · Apr 2013
Randomized Controlled Trial Multicenter Study Comparative StudyThe "final" 5-year follow-up from the ENDEAVOR IV trial comparing a zotarolimus-eluting stent with a paclitaxel-eluting stent.
- Ajay J Kirtane, Martin B Leon, Michael W Ball, Harpaul S Bajwa, Michael H Sketch, Patrick S Coleman, Robert C Stoler, Stylianos Papadakos, Donald E Cutlip, Laura Mauri, David E Kandzari, and ENDEAVOR IV Investigators.
- Columbia University Medical Center/New York Presbyterian Hospital, New York, New York 10032, USA. akirtane@columbia.edu
- JACC Cardiovasc Interv. 2013 Apr 1; 6 (4): 325-33.
ObjectivesThis study sought to report the final 5-year outcomes of the ENDEAVOR IV (A Randomized, Controlled Trial of the Medtronic Endeavor Drug [ABT-578] Eluting Coronary Stent System Versus the Taxus Paclitaxel-Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions) trial comparing the Endeavor zotarolimus-eluting stent (E-ZES) (Medtronic, Santa Rosa, California) with the Taxus paclitaxel-eluting stent (PES) (Boston Scientific, Natick, Massachusetts) in patients with single de novo coronary lesions.BackgroundPrimary results of the ENDEAVOR IV trial demonstrated similar clinical outcomes with E-ZES and PES. Concerns with regard to late adverse clinical events with drug-eluting stents highlight the need for long-term follow-up with these devices.MethodsLate outcomes after the use of E-ZES and PES were examined in the multicenter randomized ENDEAVOR IV trial in cumulative and landmark analyses. Assessed outcomes were related to device efficacy and patient safety.ResultsAt 5 years, clinical data were available for 722 (93.4%) E-ZES patients and 718 (92.6%) PES patients. Overall rates of target lesion revascularization (7.7% vs. 8.6%, p = 0.70) and target vessel failure were similar (17.2% vs. 21.1%, p = 0.061) with E-ZES compared with PES. The incidence of cardiac death or myocardial infarction (MI) was lower with E-ZES (6.4% vs. 9.1%, p = 0.048), primarily driven by a lower rate of target vessel MI with E-ZES (2.6% vs. 6.0%, p = 0.002). Although overall definite/probable stent thrombosis rates were similar between stents (1.3% vs. 2%, p = 0.42), rates of very late stent thrombosis (0.4% vs. 1.8%, p = 0.012) and late MI events (1.3% vs. 3.5%, p = 0.008) were significantly lower with E-ZES compared with PES.ConclusionsThese data demonstrate the durable efficacy and safety of E-ZES compared with PES for the treatment of de novo coronary lesions. Significant improvements in late safety outcomes were observed with E-ZES but should be considered hypothesis-generating, given the limited statistical power of the trial. (The ENDEAVOR IV Clinical Trial: A Trial of a Coronary Stent System in Coronary Artery Lesions; NCT00217269).Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.