    BackgroundThough the use of small bolus doses of vasopressors, termed "push dose pressors," has become common in emergency medicine, data examining this practice are scant. Push dose pressors frequently involve bedside dilution, which may result in errors and adverse events. The objective of this study was to assess for instances of human error and adverse hemodynamic events during push dose pressor use in the emergency department.MethodsThis was a structured chart and video review of all patients age ≥ 16 years undergoing resuscitation and receiving push dose pressors from a single center from January 2010 to November 2017. Push dose pressors were defined as intended intravenous boluses of phenylephrine (any dose) or epinephrine (≤ 100 mcg).ResultsA total of 249 patients were analyzed. Median age was 60 years (range, 16-97), 58% were male, 49% survived to discharge. Median initial epinephrine dose was 20 mcg (n = 139, IQR 10-100, range 1-100); median phenylephrine dose was 100 mcg (n = 110, IQR 100-100, range 25-10,000). Adverse hemodynamic events occurred in 98 patients (39%); 30 in the phenylephrine group (27%; 95% CI, 19-36%), and 68 in the epinephrine group (50%; 95% CI, 41-58%). Human errors were observed in 47 patients (19%), including 7 patients (3%) experiencing dosing errors (all overdoses; range, 2.5- to 100-fold) and 43 patients (17%) with a documentation error. Only one dosing error occurred when a pharmacist was present.ConclusionsHuman errors and adverse hemodynamic events were common with the use of push dose pressors in the emergency department. Adverse hemodynamic events were more common than in previous studies. Future research should determine if push dose pressors improve outcomes and if so, how to safely implement them into practice.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…