• Eur. Respir. J. · Jun 2019

    Multicenter Study

    A point-of-care neutrophil elastase activity assay identifies bronchiectasis severity, airway infection and risk of exacerbation.

    • Amelia Shoemark, Erin Cant, Luis Carreto, Alexandria Smith, Martina Oriano, Holly R Keir, Lidia Perea, Elisabet Canto, Leonardo Terranova, Silvia Vidal, Kelly Moffitt, Stefano Aliberti, Oriol Sibila, and James D Chalmers.
    • Scottish Centre for Respiratory Research, University of Dundee, Ninewells Hospital and Medical School, Dundee, UK.
    • Eur. Respir. J. 2019 Jun 1; 53 (6).

    IntroductionNeutrophil elastase activity in sputum can identify patients at high risk of airway infection and exacerbations in bronchiectasis. Application of this biomarker in clinical practice is limited, because no point-of-care test is available. We tested whether a novel semi-quantitative lateral flow device (neutrophil elastase airway test stick - NEATstik®) can stratify bronchiectasis patients according to severity, airway infection and exacerbation risk.MethodsSputum samples from 124 patients with stable bronchiectasis enrolled in the UK and Spain were tested using the NEATstik®, which scores neutrophil elastase concentration from 0 (<8 µg·mL-1 elastase activity) to 10 (maximum detectable neutrophil elastase activity). High neutrophil elastase activity was regarded as a NEATstik® grade >6. Severity of disease, airway infection from sputum culture and exacerbations over the 12 months were recorded. An independent validation was conducted in 50 patients from Milan, Italy.Measurements And Main ResultsPatients had a median age of 69 years and forced expiratory volume in 1 s (FEV1) 69%. High neutrophil elastase activity was associated with worse bronchiectasis severity using the bronchiectasis severity index (p=0.0007) and FEV1 (p=0.02). A high NEATstik® grade was associated with a significant increase in exacerbation frequency, incident rate ratio 2.75 (95% CI 1.63-4.64, p<0.001). The median time to next exacerbation for patients with a NEATstik® grade >6 was 103 days compared to 278 days. The hazard ratio was 2.59 (95% CI 1.71-3.94, p<0.001). Results were confirmed in the independent validation cohort.ConclusionsA novel lateral flow device provides assessment of neutrophil elastase activity from sputum in minutes and identifies patients at increasing risk of airway infection and future exacerbations.Copyright ©ERS 2019.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.