-
- Alessandro Della Puppa, Oriela Rustemi, and Renato Scienza.
- Department of Neurosurgery, Padua University Hospital, Padua, Italy.
- Neurosurgery. 2015 Jun 1;11 Suppl 2:268-73.
BackgroundIntraoperative quantitative flow measurement by a microvascular ultrasonic flow probe is an established methodology in aneurysm surgery.ObjectiveTo test the present flow measurement procedure in brain arteriovenous malformation (AVM) surgery.MethodsData from 25 patients with brain AVMs who consecutively underwent microsurgical resection with the assistance of flow measurement by a microflow probe were retrospectively analyzed. Flowmetry was performed on arterial feeders, potentially transit arteries, and venous drainage of AVM in different phases of resection.ResultsA quantitative flow measurement was performed 203 times on 92 vessels. Flowmetry was able to define the flow direction of AVM vessels in all cases, thereby discriminating between arterial feeders and venous drainages, both superficially and deeply located. During AVM dissection, flowmetry identified a transit artery in 12% of cases by detecting a flow drop between 2 points of the same vessel. At the final stage of resection, a residual nidus, potentially missed at surgical dissection, was detected when the flow value of venous drainage was greater than 4 mL/min (20% of patients). Pre-resection microflow probe measurements were concordant with indocyanine green videoangiography data on AVM angioarchitecture in all cases. No microflow probe-induced AVM vessel injury was reported. Complete AVM resection was achieved in all cases with a low morbidity (modified Rankin Scale score ≤ 1).ConclusionMultistage intraoperative quantitative flow measurement proved to be a feasible, safe, repeatable, and reliable methodology to assist surgery in different phases of AVM resection. Further studies are needed to assess the impact of this approach on AVM patient outcomes.VA, indocyanine green videoangiographymRS, modified Rankin ScaleSM, Spetzler Martin.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.