• JACC Cardiovasc Interv · Sep 2009

    Case Reports

    Expanding the eligibility for transcatheter aortic valve implantation the trans-subclavian retrograde approach using: the III generation CoreValve revalving system.

    • Chiara Fraccaro, Massimo Napodano, Giuseppe Tarantini, Valeria Gasparetto, Gino Gerosa, Roberto Bianco, Raffaele Bonato, Demetrio Pittarello, Giambattista Isabella, Sabino Iliceto, and Angelo Ramondo.
    • Department of Interventional Cardiology, University of Padova, Padova, Italy. chiara_fraccaro@hotmail.com
    • JACC Cardiovasc Interv. 2009 Sep 1; 2 (9): 828-33.

    ObjectivesOur aim was to assess the safety and feasibility of the retrograde trans-subclavian approach to transcatheter aortic valve implantation (TAVI) in selected high-risk patients with aortic stenosis (AS) and severe peripheral vasculopathy.BackgroundTAVI is an emerging therapeutic option to treat inoperable/high-risk patients affected by symptomatic AS. However, these patients are also often affected by severe iliac-femoral arteriopathy, rendering the transfemoral approach unemployable for percutaneous revalving procedure.MethodsFrom among those patients in our department between May 2007 and December 2008, who were refused surgical aortic valve replacement because of high surgical risk and were ineligible for transfemoral percutaneous aortic valve replacement, we scheduled 3 for TAVI by the subclavian approach. Procedures were performed by a combined team of cardiologists, cardiac surgeons, and anesthetists in the catheterization laboratory. The III generation CoreValve Revalving System (CoreValve Inc., Irvine, California) with an 18-F delivery system was introduced in all cases by the left subclavian artery.ResultsProsthetic valves were successfully implanted in all 3 cases, leading to a fall in transvalvular gradient without significant paravalvular regurgitation. No intraprocedural or periprocedural complications occurred. Two patients developed an atrioventricular block requiring the implantation of a permanent pacemaker. All patients were discharged in asymptomatic status, with good prosthesis performance. No adverse events occurred within the 3-month follow-up.ConclusionsTAVI by subclavian retrograde approach seems safe and feasible in inoperable/high-risk patients with AS and peripheral vasculopathy, who are neither eligible for surgical valve replacement nor transfemoral percutaneous aortic valve implantation. Further studies are needed to evaluate the long-term efficacy of this new therapy.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…