- Sebastian D Reinartz, Michael Imhoff, René Tolba, Felix Fischer, Eike G Fischer, Eckhard Teschner, Sabine Koch, Yvo Gärber, Peter Isfort, and Felix Gremse.
- Department of Diagnostic and Interventional Radiology, University Hospital, RWTH Aachen University, 52074, Aachen, Germany. sreinartz@ukaachen.de.
- Sci Rep. 2019 Jul 5; 9 (1): 9796.
AbstractIt is crucial to precisely monitor ventilation and correctly diagnose ventilation-related pathological states for averting lung collapse and lung failure in Intensive Care Unit (ICU) patients. Although Electrical Impedance Tomography (EIT) may deliver this information continuously and non-invasively at bedside, to date there are no studies that systematically compare EIT and Dual Energy CT (DECT) during inspiration and expiration (ΔDECT) regarding varying physiological and ICU-typical pathological conditions such as atelectasis. This study aims to prove the accuracy of EIT through quantitative identification and monitoring of pathological ventilation conditions on a four-quadrant basis using ΔDECT. In a cohort of 13 pigs, this study investigated systematic changes in tidal volume (TV) and positive end-expiratory pressure (PEEP) under physiological ventilation conditions. Pathological ventilation conditions were established experimentally by single-lung ventilation and pulmonary saline lavage. Spirometric data were compared to voxel-based entire lung ΔDECT, and EIT intensities were compared to ΔDECT of a 12-cm slab of the lung around the EIT belt, the so called ΔDECTBelt. To validate ΔDECT data with spirometry, a Pearson's correlation coefficient of 0.92 was found for 234 ventilation conditions. Comparing EIT intensity with ΔDECT(Belt), the correlation r = 0.84 was found. Normalized cross-correlation function (NCCF) between scaled global impedance (EIT) waveforms and global volume ventilator curves was r = 0.99 ± 0.003. The EIT technique correctly identified the ventilated lung in all cases of single-lung ventilation. In the four-quadrant based evaluation, which assesses the difference between end-expiratory lung volume (ΔEELV) and the corresponding parameter in EIT, i.e. the end-expiratory lung impedance (ΔEELI), the Pearson's correlation coefficient of 0.94 was found. The respective Pearson's correlation coefficients implies good to excellent concurrence between global and regional EIT ventilation data validated by ventilator spirometry and DECT imaging. By providing real-time images of the lung, EIT is a promising, EIT is a promising, clinically robust tool for bedside assessment of regional ventilation distribution and changes of end-expiratory lung volume.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.