-
- Aude Tonson la Tour, Marie Pier Desjardins, and Jocelyn Gravel.
- Division of Pediatric Emergency Medicine, Children's Hospital of Geneva, Geneva University Hospitals, Geneva, Switzerland.
- Acad Emerg Med. 2021 Aug 1; 28 (8): 866-872.
ObjectiveThe aim of our study was to evaluate the test characteristics of point-of-care ultrasound (POCUS) performed by emergency physicians with varying levels of experience among children having undergone diagnostic radiology ultrasound for intussusception in a pediatric emergency department (PED).MethodsThis was a subanalysis of a prospective cohort study conducted at a tertiary care PED. The study population was a sample of children younger than 5 years old who required an abdominal ultrasound for suspected intussusception. Participating physicians had varying levels of POCUS experience. They received a 1-hour didactic and practical training session on intussusception ultrasound. All POCUS was performed following the initial physical examination and prior to further radiologic evaluation. The final outcome was determined by radiologic evaluation performed by a pediatric radiologist. Test characteristics were calculated for POCUS compared with the criterion standard of ultrasound read by a pediatric radiologist. A secondary analysis compared test characteristics of POCUS performed by physicians with different level of POCUS training.ResultsA total of 131 children were evaluated by POCUS, of whom 45 (34%) had an intussusception. Twenty-four physicians performed between one and 25 POCUS procedures. POCUS identified 39 of 45 intussusception cases, with a sensitivity of 0.87 (95% confidence interval [CI] = 0.74 to 0.94). A normal or inconclusive POCUS was reported for 83 of the 86 negative studies, with a specificity of 0.97 (95% CI = 0.90 to 0.99). When excluding the 28 patients for whom the physician reported an inconclusive examination, the sensitivity improved to 0.98 (95% CI = 0.97 to 1.00) and the specificity to 0.94 (95% CI = 0.85 to 0.99). The accuracy of diagnosis using POCUS was 42 of 43 (98%) for experienced sonographers in comparison to 81 of 88 (92%) for novices.ConclusionThis study demonstrated a very good sensitivity and specificity of POCUS for intussusception in children when performed by multiple emergency physicians with varying POCUS experience.© 2021 by the Society for Academic Emergency Medicine.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.