-
Multicenter Study
Evaluation of the presence of sacroiliac joint region dysfunction using a combination of tests: a multicenter intertester reliability study.
- Daniel L Riddle and Janet K Freburger.
- Department of Physical Therapy, Medical College of Virginia Campus, Virginia Commonwealth University, 1200 E Broad St, Richmond, VA 23298-0224, USA. driddle@hsc.vcu.edu
- Phys Ther. 2002 Aug 1; 82 (8): 772-81.
Background And PurposeThe authors examined the intertester reliability of assessments made based on a composite of 4 tests of pelvic symmetry or sacroiliac joint (SIJ) movement that are advocated in the literature for identifying people with SIJ region dysfunction. "Sacroiliac joint region dysfunction" is a term used to describe pain in or around the region of the joint that is presumed to be due to malalignment or abnormal movement of the SIJs.SubjectsSixty-five patients with low back pain and unilateral buttock pain were seen in 1 of 11 outpatient clinics.MethodsThirty-four therapists, randomly paired for each subject, served as examiners. Kappa coefficients and observed proportions of positive (Ppos) and negative (Pneg) agreement were calculated to estimate reliability.ResultsFor the composite test results, percentages of agreement ranged from 60% to 69%, kappa coefficients varied from.11 to.23, and Ppos was lower than 50%.Discussion And ConclusionReliability of measurements obtained with the 4 tests appears to be too low for clinical use. Given the measurement error found in this study, the authors suspect it is likely that either the proper treatment technique will not be chosen based on the test results or the intervention will be applied to the wrong side. The 4 tests probably should not be used to examine patients suspected of having SIJ region dysfunction, although the role of therapist training in use of the procedures is unclear.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.