    Evaluation of the mode of failure of abutments supporting implant-supported fixed partial dentures via different retention techniques.

    • F Alqahtani and M AlHomidhi.
    • Department of Prosthodontics, College of Dentistry, Prince Sattam Bin Abdulaziz University, Al-Kharj, Saudi Arabia.
    • Niger J Clin Pract. 2021 Feb 1; 24 (2): 220-224.

    ObjectiveThe objective was to in-vitro evaluate the mode of failure of abutments supporting fixed partial dentures (FPDs) via different retention techniques.Materials And MethodsThirty-six implants with diameter and length of 4.5 and 13 mm, respectively, were used to prepare 18 samples of FPDs. Based on the variations on abutment's design, the FPDs were divided into three groups: Group A is cement-based retention; Group B is screw-based retention; and Group C is multiunit screw-based retention. Using a chewing simulator, cyclic loads of 1,250,000 load cycles with the load of 70N were applied on all samples to simulate 5 years of human functional chewing. The samples were loaded until failure using an electromechanical test machine. Sample-size estimation was done and fracture-load values were recorded as means and corresponding standard deviations; and group comparisons were done using one-way analysis of variance and Tukey's post hoc tests. A P value below 0.01 was nominated as an indicator of statistical significance.ResultsIn total, 36 samples (12 implant-abutment connections per group) were assessed. Abutment bending was observed in 6 (50%), 6 (50%) and 6 (50%) samples in groups A, B and C, respectively. De-attachment of the FPD form the abutment occurred in 5 (41.7%) and 5 (41.7%) samples in groups A and C, respectively. Screw fracture and fracture of FPD at the connector side occurred in 1 (8.3%) and 1 (8.3%) sample in groups A and C, correspondingly. Failure of the FPD was more often encountered in groups A (100%) and C (100%), compared to group B (50%).ConclusionAll abutments underwent failures under cyclic loading with abutment bending being the most common failure mode. Cement- and multi-screw-supported abutments fail more often than screw-supported abutments.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…