          IEEE Trans Ultrason Ferroelectr Freq Control · Feb 2015 Two-dimensional shear-wave elastography on conventional ultrasound scanners with time-aligned sequential tracking (TAST) and comb-push ultrasound shear elastography (CUSE).- Pengfei Song, Michael Macdonald, Russell Behler, Justin Lanning, Michael Wang, Matthew Urban, Armando Manduca, Heng Zhao, Matthew Callstrom, Azra Alizad, James Greenleaf, and Shigao Chen.
- IEEE Trans Ultrason Ferroelectr Freq Control. 2015 Feb 1; 62 (2): 290-302.
 AbstractTwo-dimensional shear-wave elastography presents 2-D quantitative shear elasticity maps of tissue, which are clinically useful for both focal lesion detection and diffuse disease diagnosis. Realization of 2-D shear-wave elastography on conventional ultrasound scanners, however, is challenging because of the low tracking pulse-repetition-frequency (PRF) of these systems. Although some clinical and research platforms support software beamforming and plane-wave imaging with high PRF, the majority of current clinical ultrasound systems do not have the software beamforming capability, which presents a critical challenge for translating the 2-D shear-wave elastography technique from laboratory to clinical scanners. To address this challenge, this paper presents a time-aligned sequential tracking (TAST) method for shear-wave tracking on conventional ultrasound scanners. TAST takes advantage of the parallel beamforming capability of conventional systems and realizes high-PRF shear-wave tracking by sequentially firing tracking vectors and aligning shear wave data in the temporal direction. The comb-push ultrasound shear elastography (CUSE) technique was used to simultaneously produce multiple shear wave sources within the field-of-view (FOV) to enhance shear wave SNR and facilitate robust reconstructions of 2-D elasticity maps. TAST and CUSE were realized on a conventional ultrasound scanner. A phantom study showed that the shear-wave speed measurements from the conventional ultrasound scanner were in good agreement with the values measured from other 2-D shear wave imaging technologies. An inclusion phantom study showed that the conventional ultrasound scanner had comparable performance to a state-of-the-art shear-wave imaging system in terms of bias and precision in measuring different sized inclusions. Finally, in vivo case analysis of a breast with a malignant mass, and a liver from a healthy subject demonstrated the feasibility of using the conventional ultrasound scanner for in vivo 2-D shear-wave elastography. These promising results indicate that the proposed technique can enable the implementation of 2-D shear-wave elastography on conventional ultrasound scanners and potentially facilitate wider clinical applications with shear-wave elastography. Notes
 Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes- Simple formatting can be added to notes, such as *italics*,_underline_or**bold**.
- Superscript can be denoted by <sup>text</sup>and subscript<sub>text</sub>.
- Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens-or asterisks*.
- Links can be included with: [my link to pubmed](http://pubmed.com)
- Images can be included with: 
- For footnotes use [^1](This is a footnote.)inline.
- Or use an inline reference [^1]to refer to a longer footnote elseweher in the document[^1]: This is a long footnote..