Arch Cardiovasc Dis · Oct 2017
Two-year clinical outcome after a single cryoballoon ablation procedure: A comparison of first- and second-generation cryoballoons.
- Alexandre Zhao, Fabien Squara, Eloi Marijon, and Olivier Thomas.
- Clinique Ambroise-Paré, 25-27 boulevard Victor-Hugo, 92200 Neuilly-sur-Seine, France; Cardiology department and Paris Cardiovascular Research Centre, European Georges-Pompidou Hospital, Paris, France. Electronic address: alexandre.zhao@gmail.com.
- Arch Cardiovasc Dis. 2017 Oct 1; 110 (10): 543-549.
BackgroundThe ablation of paroxysmal atrial fibrillation (PAF) by cryoballoon has increased dramatically in recent years. However, there are few data comparing first- and second-generation cryoballoons.AimTo compare safety and mid-term (2-year) efficacy of first- and second-generation cryoballoons in PAF ablation, using cryoballoon size tailored to pulmonary vein anatomy.MethodsIn this single-centre study, we included the last 50 consecutive PAF patients who underwent cryoballoon-based pulmonary vein isolation using the first-generation cryoballoon (CB-1) and the first 50 patients using the second-generation cryoballoon (CB-2). The choice of 23 or 28mm cryoballoon was driven by patient anatomy. After discharge, follow-up was with systematic outpatient visits at 3, 6, 9, 12 and 24 months, including 12-lead electrocardiogram, Holter monitoring and telephone interviews, plus additional electrocardiograms, as required, in case of symptoms. Arrhythmia recurrence was defined as a documented atrial tachycardia or fibrillation episode>30seconds after a 3-month blanking period.ResultsAt 24 months, freedom from arrhythmia after a single procedure was similar for both generations of cryoballoon (72.0% and 72.0% for CB-1 and CB-2, respectively; P=0.95). Mean procedure and fluoroscopy times were longer in the CB-1 group than in the CB-2 group: 139±37.8 vs 95.2±21.3minutes and 10.2±7.2 vs 5.1±2.4minutes, respectively (P<0.02 for both). Transient right phrenic nerve palsy occurred only in the CB-1 group (five patients, 9.8%).ConclusionsCB-1 and CB-2 showed similar efficacy for PAF ablation, with similar arrhythmia recurrence 24 months after a single ablation procedure. However, our findings suggest that CB-2 may have more effective cooling capabilities, enabling shorter procedure and fluoroscopy times.Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.