-
Diabetes Metab. Res. Rev. · Oct 2010
Glucose effectiveness and insulin sensitivity measurements derived from the non-insulin-assisted minimal model and the clamp techniques are concordant.
- Jan Erik Henriksen, Frank Alford, Glenn Ward, Peter Thye-Rønn, Klaus Levin, Ole Hother-Nielsen, Christian Rantzau, Ray Boston, and Henning Beck-Nielsen.
- Department of Endocrinology M, Diabetes Research Centre, Odense University Hospital, Odense C, Denmark. jan.erik.henriksen@ouh.regionsyddanmark.dk
- Diabetes Metab. Res. Rev. 2010 Oct 1; 26 (7): 569-78.
BackgroundWe investigated the concordance between glucose effectiveness (SG) and insulin sensitivity (SI), derived from the unmodified dynamic non-insulin-assisted intravenous glucose tolerance test (IVGTT) implemented by SG(MM) and SI(MM); simulation analysis and modelling/conversational interaction (SAAM/CONSAM) versus the eu/hyperglycaemic basal insulinaemic and the euglycaemic hyperinsulinaemic clamp (SG(CLAMP) and SI(CLAMP)).MethodsTwenty-seven of 30 normoglycaemic subjects completed a (1) euglycaemic hyperinsulinaemic clamp, (2) 6-h eu/hyperglycaemic near-normoinsulinaemic pancreatic clamp with hyperglycaemia present over the final 2 h of the clamp (Day 2 study), (3) identical clamp to (2) but with euglycaemia maintained over the entire 6 h (Day 3 study) and (4) IVGTT. SG(CLAMP) was calculated in two ways based on data from study (2) alone (Day 2 SG(CLAMP210-240')) or from data from study day (2) and (3) (Day 2-3 SG(CLAMP330-360')).ResultsSG(MM) was unrelated to the magnitude of endogenous insulin release (AIR). The single-day (Day 2) and two-day (Day 2 and 3) SG(CLAMP) protocols correlated (r = 0.72, p = 0.003), but SG(CLAMP210-240') was significantly (p = 0.001) higher than SG(CLAMP330-360'). Employing the Day 2 and 3 SG(CLAMP) protocol, the whole body SG(CLAMP330-360') was similar to SG(MM) (1.80 ± 0.82 versus 1.73 ± 0.58 dL/min) and correlated (r = 0.45, p < 0.02). SG(CLAMP210-240') did not correlate with SG(MM) (r = 0.24). SI(MM) and SI(CLAMP) were similar (0.093 ± 0.060 versus 0.087 ± 0.029 dL/min per mU/L) and correlated (r = 0.76, p < 0.001).ConclusionsThe time-dependent increase in glucose disposal observed during a prolonged 6-h clamp significantly influences the estimation of SG(CLAMP), and significant concordance coefficients are observed between SG(MM), and SG(CLAMP330-360'), and SI(MM) and SI(CLAMP).
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.