• J Interv Card Electrophysiol · Dec 2016

    Multicenter Study Comparative Study

    Pulmonary vein reconnection following catheter ablation of atrial fibrillation using the second-generation cryoballoon versus open-irrigated radiofrequency: results of a multicenter analysis.

    • Arash Aryana, Sheldon M Singh, Giacomo Mugnai, Carlo de Asmundis, Marcin Kowalski, Deep K Pujara, Andrew I Cohen, Steve K Singh, Charles E Fuenzalida, Nelson Prager, Mark R Bowers, Padraig Gearoid O'Neill, Pedro Brugada, André d'Avila, and Gian-Battista Chierchia.
    • Department of Cardiology and Cardiovascular Surgery, Mercy General Hospital and Dignity Health Heart and Vascular Institute, 3941 J Street, Suite #350, Sacramento, CA, 95819, USA. a_aryana@outlook.com.
    • J Interv Card Electrophysiol. 2016 Dec 1; 47 (3): 341-348.

    PurposeCatheter ablation of atrial fibrillation (CAAF) using the cryoballoon has emerged as an alternate strategy to point-by-point radiofrequency. However, there is little comparative data on long-term durability of pulmonary vein (PV) isolation comparing these two modalities.MethodsIn this multicenter, retrospective analysis, the incidences/patterns of late PV reconnection following an index CAAF using the second-generation cryoballoon versus open-irrigated, non-force-sensing radiofrequency were examined.ResultsOf the 2002 patients who underwent a first-time CAAF, 186/1126 patients (16.5 %) ablated using cryoballoon and 174/876 patients (19.9 %) with non-contact force-guided radiofrequency required a repeat procedure at 11 ± 5 months. During follow-up, the incidence of atrial flutters/tachycardias was lower (19.9 vs. 32.8 %; p = 0.005) and fewer patients exhibited PV reconnection (47.3 vs. 60.9 %; p = 0.007) with cryoballoon versus radiofrequency. Additionally, fewer PVs had reconnected with cryoballoon versus radiofrequency (18.8 vs. 34.6 %; p < 0.001). With cryoballoon, the right inferior (p < 0.001) and left common (p = 0.039) PVs were more likely to exhibit late reconnection, versus the left superior PV with radiofrequency (p = 0.012). However, when comparing the two strategies, the left common PV was more likely to exhibit reconnection with cryoballoon, whereas all other PVs with the exception of the right inferior PV demonstrated a lower reconnection rate with cryoballoon versus radiofrequency. Lastly, in a logistic regression multivariate analysis, cryoballoon ablation and PV ablation time emerged as significant predictors of durable PV isolation at repeat procedure.ConclusionsIn this large multicenter, retrospective analysis, CAAF using the second-generation cryoballoon was associated with improved durability of PV isolation compared to open-irrigated, non-force-sensing radiofrequency.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…