• Pediatric pulmonology · Jul 2018

    Accuracy of oscillatory pressure measured by mechanical ventilators during high frequency oscillatory ventilation in newborns.

    • Chiara Veneroni, Marta Tossici, Emanuela Zannin, Ilaria Milesi, and Raffaele L Dellaca'.
    • Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano University, Milano, Italy.
    • Pediatr. Pulmonol. 2018 Jul 1; 53 (7): 901-906.

    BackgroundOscillatory pressure (ΔP) measurement during high frequency oscillatory ventilation (HFOV) is technically challenging and influenced by all the components of the measurement system.ObjectivesTo evaluate the differences between the ΔP delivered at the inlet of the endotracheal tube and those displayed by commercial neonatal mechanical ventilators and monitoring devices and to characterize how the ventilator circuit and the flowmeter proximal to the patient affect these differences.MethodsSix devices were evaluated while ventilating three mechanical analogues representing the newborn respiratory system in different disease states. ΔP measured at different points of the ventilator circuit were compared.ResultsΔP accuracy is highly variable and decreases with increasing oscillation frequency and amplitude, independently of the mean airway pressure. At 15 Hz, a ΔP displayed by ventilators of 40 cmH2 O resulted in a ΔP effectively delivered at the tracheal tube ranging from 22 to 49 cmH2 O, depending on the ventilator model, the ventilator circuit, and the patient condition. At these settings, the errors exclusively due to the ventilator circuit and the presence of the flowmeter ranged from 6 to 9 cmH2 O and from 1 to 6 cmH2 O, respectively.ConclusionsThe ventilator model, the breathing circuit, the flowmeter, and the patient condition severely impacts ΔP measurement accuracy during HFOV, leading to highly variable performances. This prevents the possibility of using the ΔP required to normalize gas exchange as an indicator of patients' condition, complicates comparison of ventilators performances, and adds a significant element of complexity in clinical management of HFOV.© 2018 Wiley Periodicals, Inc.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…