    BackgroundExposure of blood to artificial surfaces, as in cardiopulmonary bypass, induces an inflammatory response involving complement, leukocyte and platelet activation. To elucidate the specific role of complement in this process, studies were performed on blood circulated in polyvinyl chloride tubing in the absence and presence of complement inhibitors. Parallel experiments were performed with heparin-coated polyvinyl chloride tubing, which is known to prevent complement and cell activation.MethodsA novel experimental model was used, based on human whole blood anticoagulated with lepirudin. Complement activation products, myeloperoxidase, lactoferrin, and thrombospondin were quantified in enzyme immunoassays. Leukocyte CD11b expression and leukocyte-platelet conjugates were detected by flow cytometry.ResultsIncreased levels of C3 activation products, alternative pathway convertase, and the terminal SC5b-9 complex, combined with unchanged levels of C1rs-C1-inhibitor complexes and marginal changes in C4 activation demonstrated that complement was activated through the alternative pathway. Granulocyte and monocyte CD11b expression and granulocyte-platelet conjugate formation were efficiently attenuated by blocking either factor D, C3, C5, or C5a receptor. In contrast, monocyte-platelet conjugate formation and release of myeloperoxidase, lactoferrin, and thrombospondin were not reduced by complement inhibition. Heparin-coated polyvinyl chloride tubing efficiently reduced all inflammatory markers studied, except for C1rs-C1-inhibitor complexes, which increased, consistent with the enhancing effect of heparin on C1-inhibitor function. This effect did not, however, reduce fluid-phase classic pathway activation induced by heat-aggregated immunoglobulin G.ConclusionsLeukocyte and platelet activation in response to artificial materials occur by mechanisms that vary in their dependence on complement. Heparin coating precludes both the complement-dependent and complement-independent reactions.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,706,642 articles already indexed!

We guarantee your privacy. Your email address will not be shared.