• Chest · May 1998

    Randomized Controlled Trial Comparative Study Clinical Trial

    Assessment of three methods to reduce the influence of mathematical coupling on oxygen consumption and delivery relationships.

    • J T Granton, K R Walley, P T Phang, J A Russell, and S Lichtenstein.
    • Division of Cardiac Surgery, St. Paul's Hospital, University of British Columbia, Vancouver, Canada. j.granton@utoronto.ca
    • Chest. 1998 May 1; 113 (5): 1347-55.

    Study ObjectivesTo determine if oxygen consumption/oxygen delivery (VO2/DO2) relationships derived using calorimetry (which are not influenced by shared measurement error) agreed with those obtained using the pulmonary artery (PA) catheter alone. To evaluate three strategies to reduce the influence of shared measurement error to determine if agreement between the two methods could be improved.MethodsTwenty-seven patients were studied following coronary artery bypass surgery. Calorimetric VO2, six thermodilution cardiac outputs (COs), and arterial and mixed venous oxygen content measurements were made at baseline and were repeated 30 min following dobutamine administrations of 3 microg/kg/min and 5 microg/kg/min.ResultsDobutamine produced a dose-dependent increase in DO2, from 378+/-65 mL/min/m2 to 446+/-78 mL/min/m2 (p<0.01) and in both PA catheter and calorimetric-derived VO2, from 104+/-18 mL/min/Mi2 to 114+/-22 mL/min/m2 (p<0.05) and from 117+/-15 mL/min/m2 to 126+/-19 mL/min/m2 (p<0.01), respectively. Agreement was poor (bias=12%, SD=21%) between the calorimetric and PA catheter methods of determining VO2/DO2 slope. When three CO measurements were used to calculate VO2, and three separate CO measurements were used to calculate DO2, the level of agreement between the two methods improved (bias=2%, SD=15%). Increasing the number of COs resulted in a similar improvement in the level of agreement between the two methods. Weighting the slope to the observed change in DO2 was the best method to improve the level of agreement (bias=2%, SD=6% for three COs).ConclusionsTo reduce the influence of shared measurement error, the best strategy to improve the measurement of VO2/DO2 slope is to maximize the change in DO2 (optimally over 100 mL/min/m2).

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?

    User can't be blank.

    Content can't be blank.

    Content is too short (minimum is 15 characters).

    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.