J. Thorac. Cardiovasc. Surg. · Apr 2015
Comparative StudyCharacterization of ventricular assist device-mediated sensitization in the bridge-to-heart-transplantation patient.
- Murray H Kwon, Jennifer Q Zhang, Joanna M Schaenman, Martin Cadeiras, David W Gjertson, Carolyn A Krystal, Hillel Laks, Abbas Ardehali, Mario C Deng, Richard J Shemin, and Elaine F Reed.
- Division of Cardiothoracic Surgery, Department of Surgery, David Geffen School of Medicine at the University of California, Los Angeles, Los Angeles, Calif. Electronic address: mkwon@mednet.ucla.edu.
- J. Thorac. Cardiovasc. Surg. 2015 Apr 1; 149 (4): 1161-6.
ObjectiveVentricular assist devices (VADs) are associated with increased anti-human leukocyte antigen antibody production. The purpose of this study is to characterize differences in sensitization patterns in patients receiving axial flow, implantable VADs versus pulsatile, paracorporeal biventricular assist devices (BIVADs) as bridges to transplantation.MethodsThe study is a retrospective review of 68 patients who were bridged to transplantation with either a VAD or a BIVAD, as described, from January 2007 to June 2010, at a university medical center.ResultsFive of 15 (33.3%) VAD patients became sensitized during treatment, compared with 30 of 53 (56.6%) BIVAD patients, P = .15. Multivariable analysis comparing BIVAD with VAD, while controlling for previous cardiac surgery, pregnancy, and packed red blood cell transfusion produced an odds ratio of 2.99, P = .14. Of sensitized patients, all 5 (100%) of the VAD patients had pre-existing antibodies before VAD placement, compared with 9 of 30 (30.0%) BIVAD patients, P = .006. Maximum cumulative mean fluorescence intensities for BIVAD were 46,259 ± 66,349 versus 42,540 ± 12,840 for VAD, P = .90. Time to maximum antibody expression was shorter for the VAD group (34 ± 28 days vs 5.8 ± 9 days, P = .04).ConclusionsDevice type was not a factor in patient sensitization after implantation. However, VAD patients required pre-existing sensitization before implantation to produce antibodies during their treatment interval, whereas more than two thirds of BIVAD patients developed de novo antibodies. These data suggest that the mechanism of sensitization between VAD and BIVAD patients may differ, and further mechanistic studies into the impact of device types on patient sensitization are warranted.Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.