• Annals of surgery · Dec 2014

    Standardized practice design with electronic support mechanisms for surgical process improvement: reducing mechanical ventilation time.

    • David J Cook, Juan N Pulido, Jeffrey E Thompson, Joseph A Dearani, Matthew J Ritter, Andrew C Hanson, Bijan J Borah, and Elizabeth B Habermann.
    • *Department of Anesthesiology and Center for the Science of Health Care Delivery, Division of Cardiovascular Anesthesiology, Mayo Clinic College of Medicine, Rochester, MN †Department of Anesthesiology, Division of Cardiovascular Anesthesiology, Mayo Clinic College of Medicine, Rochester, MN ‡United Surgical Partners Inc, Addison, TX §Department of Surgery, Division of Cardiovascular Surgery, Mayo Clinic College of Medicine, Rochester, MN ‖Division of Biomedical Statistics and Informatics, Mayo Clinic College of Medicine, Rochester, MN ¶Health Services Research, Mayo Clinic Robert D. and Patricia E. Kern Center for the Science of Health Care Delivery, Mayo Clinic College of Medicine, Rochester, MN.
    • Ann. Surg.. 2014 Dec 1;260(6):1011-5.

    BackgroundHospital surgical care is complex and subject to unwarranted variation.ObjectiveAs part of a multiyear effort, we sought to reduce variability in intraoperative care and management of mechanical ventilation in cardiac surgery. We identified a patient population whose care could be standardized and implemented a protocol-based practice model reinforced by electronic mechanisms.MethodsIn a large cardiac surgery practice, we built a standardized practice model between 2009 and 2011. We compared mechanical ventilation time before (2008) and after (2012) implementation. To ensure groups were comparable, propensity analysis matched patients from the 2 operative years.ResultsIn 2012, more than 50% of all cardiac surgical patients were managed with our standardized care model; of those, 769 were one-to-one matched with patients undergoing surgery in 2008. Patients had a mix of coronary artery bypass grafting, valve surgery, and combined procedures. Our practice model reduced median mechanical ventilation duration from 9.3 to 6.3 hours (2008 and 2012) (P < 0.001) and intensive care unit length of stay from 26.3 to 22.5 hours (P < 0.001). Reintubation and intensive care unit readmission were unchanged. Variability in ventilation time was also reduced.ConclusionsWe demonstrate that in more than 50% of all cardiac surgical patients, a standardized practice model can be used to achieve better results. Clinical outcomes are improved and unwarranted variability is reduced. Success is driven by clear patient identification and well-defined protocols that are clearly communicated both by electronic tools and by empowerment of bedside providers to advance care when clinical criteria are met.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,706,642 articles already indexed!

We guarantee your privacy. Your email address will not be shared.