    BackgroundPreoperative simulation warm-up has been shown to improve performance and reduce errors in novice and experienced surgeons, yet existing studies have only investigated conventional laparoscopy. We hypothesized that a brief virtual reality (VR) robotic warm-up would enhance robotic task performance and reduce errors.Study DesignIn a 2-center randomized trial, 51 residents and experienced minimally invasive surgery faculty in General Surgery, Urology, and Gynecology underwent a validated robotic surgery proficiency curriculum on a VR robotic simulator and on the da Vinci surgical robot (Intuitive Surgical Inc). Once they successfully achieved performance benchmarks, surgeons were randomized to either receive a 3- to 5-minute VR simulator warm-up or read a leisure book for 10 minutes before performing similar and dissimilar (intracorporeal suturing) robotic surgery tasks. The primary outcomes compared were task time, tool path length, economy of motion, technical, and cognitive errors.ResultsTask time (-29.29 seconds, p = 0.001; 95% CI, -47.03 to -11.56), path length (-79.87 mm; p = 0.014; 95% CI, -144.48 to -15.25), and cognitive errors were reduced in the warm-up group compared with the control group for similar tasks. Global technical errors in intracorporeal suturing (0.32; p = 0.020; 95% CI, 0.06-0.59) were reduced after the dissimilar VR task. When surgeons were stratified by earlier robotic and laparoscopic clinical experience, the more experienced surgeons (n = 17) demonstrated significant improvements from warm-up in task time (-53.5 seconds; p = 0.001; 95% CI, -83.9 to -23.0) and economy of motion (0.63 mm/s; p = 0.007; 95% CI, 0.18-1.09), and improvement in these metrics was not statistically significantly appreciated in the less-experienced cohort (n = 34).ConclusionsWe observed significant performance improvement and error reduction rates among surgeons of varying experience after VR warm-up for basic robotic surgery tasks. In addition, the VR warm-up reduced errors on a more complex task (robotic suturing), suggesting the generalizability of the warm-up.Copyright © 2013 American College of Surgeons. All rights reserved.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…