• Anesthesia and analgesia · Dec 1996

    Comparative Study

    Transesophageal echocardiography: an objective tool in defining maximum ventricular response to intravenous fluid therapy.

    • J D Swenson, C Harkin, N L Pace, K Astle, and P Bailey.
    • Department of Anesthesiology, University of Utah Medical Center, Salt Lake City 84132, USA.
    • Anesth. Analg. 1996 Dec 1; 83 (6): 1149-53.

    AbstractVentricular preload is an important determinant of cardiac function, which is indirectly measured in the clinical setting by the pulmonary capillary wedge pressure (PCWP). Transesophageal echocardiography (TEE) is rapidly gaining acceptance as a monitor of cardiac function. Although it provides high-resolution images of cardiac structures, clinical assessment of ventricular preload using TEE has been subjective, since quantitative measurements have been difficult to perform in a timely fashion. Automated border detection (ABD) is a new technology used in conjunction with TEE that allows quantitative real-time, two-dimensional measurement of cavity areas. To determine whether enddiastolic area (EDA) measured by ABD can be used to determine an appropriate end point for intravenous fluid administration, nine mongrel dogs were studied. Anesthetized animals were hemorrhaged to achieve a central venous pressure of 0-5 mm Hg. Each animal was then given intravenous fluid (autologous blood followed by hetastarch) until a peak in thermodilution cardiac output (CO) was achieved. Measures of PCWP, EDA, CO, and left ventricular stroke work (LVSW) were obtained after each fluid bolus. Bivariate plots displaying administered volume versus CO, LVSW, and EDA revealed parallel curves for each of these variables with peaks evident at cumulative volumes of 50-55 mL/kg. Multiple regression with mixed model analysis of covariance was performed to determine the significance of EDA in relation to changes in CO and LVSW. Analysis was likewise performed comparing the relationship between PCWP and changes in CO or LVSW. A significant relationship was demonstrated when comparing EDA to changes in CO and LVSW (P = 0.03 and P < 0.0001, respectively). Similar analysis comparing PCWP to changes in CO and LVSW failed to demonstrate a significant relationship (P = 0.54 and P = 0.36, respectively). These data suggest that changes in EDA measured using TEE with ABD are related to trends in cardiac function and can suggest an appropriate end point for intravenous fluid administration as defined by maximum CO and LVSW. PCWP did not demonstrate a significant relationship to changes in CO and LVSW.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…