J Cardiothorac Surg · May 2009
Sternal plating for primary and secondary sternal closure; can it improve sternal stability?
- Hosam Fawzy, Nasser Alhodaib, C David Mazer, Alana Harrington, David Latter, Daniel Bonneau, Lee Errett, and James Mahoney.
- Division of Cardiovascular and Thoracic Surgery, Department of Surgery, Terrence Donnelly Heart Center, Keenan Research Center in the Li Ka Shing Knowledge Institute of St Michael's Hospital, University of Toronto, Ontario, Canada. hosamfawzy@hotmail.com
- J Cardiothorac Surg. 2009 May 7; 4: 19.
BackgroundSternal instability with mediastinitis is a very serious complication after median sternotomy. Biomechanical studies have suggested superiority of rigid plate fixation over wire cerclage for sternal fixation. This study tests the hypothesis that sternal closure stability can be improved by adding plate fixation in a human cadaver model.MethodsMidline sternotomy was performed in 18 human cadavers. Four sternal closure techniques were tested: (1) approximation with six interrupted steel wires; (2) approximation with six interrupted cables; (3) closure 1 (wires) or 2 (cables) reinforced with a transverse sternal plate at the sixth rib; (4) Closure using 4 sternal plates alone. Intrathoracic pressure was increased in all techniques while sternal separation was measured by three pairs of sonomicrometry crystals fixed at the upper, middle and lower parts of the sternum until 2.0 mm separation was detected. Differences in displacement pressures were analyzed using repeated measures ANOVA and Regression Coefficients.ResultsIntrathoracic pressure required to cause 2.0 mm separation increased significantly from 183.3 +/- 123.9 to 301.4 +/- 204.5 in wires/cables alone vs. wires/cables plus one plate respectively, and to 355.0 +/- 210.4 in the 4 plates group (p < 0.05). Regression Coefficients (95% CI) were 120 (47-194) and 142 (66-219) respectively for the plate groups.ConclusionTransverse sternal plating with 1 or 4 plates significantly improves sternal stability closure in human cadaver model. Adding a single sternal plate to primary closure improves the strength of sternal closure with traditional wiring potentially reducing the risk of sternal dehiscence and could be considered in high risk patients.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.