• Artificial organs · Sep 2001

    Effects of left ventricular assist device on cardiac function: experimental study of relationship between pump flow and left ventricular diastolic function.

    • A Saito, M Shiono, Y Orime, S Yagi, K I Nakata, K Eda, T Hattori, M Funahashi, Y Taniguchi, N Negishi, and Y Sezai.
    • The Second Department Surgery and Animal Experimental Laboratory, Nihon University School of Medicine, 30-1 Oyaguchi, Kami-machi, Itabashi-ku, Tokyo 173-8610, Japan.
    • Artif Organs. 2001 Sep 1; 25 (9): 728-32.

    AbstractThe left ventricular assist device (LVAD) with centrifugal pump has two characteristics. One is a pump flow wave of the centrifugal pump, consisting of the pulsatile flow of the native heart and the nonpulsatile flow of the centrifugal pump. The other is that the centrifugal pump fills from the native heart not only in the systolic phase, but also in the diastolic phase. In the case of the apex outlet LVAD with centrifugal pump, blood flows from the left atrium through the left ventricle to the pump. Pump flow is regulated by preload, and preload is regulated by diastolic hemodynamics. The aim of this study is to analyze the relationship between pump flow and the diastolic hemodynamics of the native heart. Ten anesthetized intact pigs were studied after placement of an LVAD. Data were recorded with the LVAD off (control) and the LVAD on. The assist rate was changed to 25%, 50%, and 75%. The indexes of left ventricular (LV) diastolic function included LV myocardial relaxation (time constant of isovolumic pressure decay [Tau] and maximum negative dP/dt [LV dP/dt min]) and LV filling (peak filling rate [PFR], time to peak filling rate [tPFR], and diastolic filling time [DFT]). Stroke volume decreased significantly in 75% assist. LV end-systolic pressure decreased significantly in 50% and 75% assist. LV end-diastolic volume decreased as assist rate increased, but there were no significant changes. Stroke work decreased significantly in 50% and 75% assist. LV dP/dt min decreased significantly in 50% and 75% assist. Tau prolonged as assist rate increased, but there were no significant changes. DFT shortened significantly in 75% assist. PFR increased significantly in 75% assist. tPFR shortened significantly in 50% and 75% assist. In this study, LV relaxation delayed as an increasing of pump assist rate, but it suggested a result of reduction of cardiac work. Also, it was suggested that LVAD increases the pressure difference between the left atrium and the left ventricle in the diastolic phase. This phenomenon is due to the filling of the left ventricle. In this study it was suggested that as pump assist rate increases, it is more effective to keep cardiac function in the diastolic phase.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.