-
J. Thorac. Cardiovasc. Surg. · Feb 2014
Differences in aortic cusp coaptation between the reimplantation and the remodeling techniques of aortic valve-sparing surgery: an in vitro porcine model study.
- Daniele Maselli, Luca Weltert, Raffaele Scaffa, Saverio Nardella, Lorenzo Guerrieri Wolf, and Ruggero De Paulis.
- Department of Cardiac Surgery, European Hospital, Rome, Italy. Electronic address: 4maselli@gmail.com.
- J. Thorac. Cardiovasc. Surg.. 2014 Feb 1;147(2):615-8.
ObjectivesWe sought to evaluate the effects of the reimplantation type versus the remodeling type of aortic valve-sparing technique on the geometry of the same aortic root.MethodsFifteen fresh isolated porcine hearts with normal aortic valves and a standard aortoventricular junction size of 23 mm were processed. An aortic valve-sparing replacement was performed by reimplanting the native aortic root inside a 28-mm Valsalva graft (Vascutek Ltd, Renfrewshire, UK). Hearts were subsequently implanted with instruments in a test circuit, and the aortic roots were pressurized at a fixed pressure of 100 mm Hg. Diameters of the aortoventricular junction, of the sinuses, and of the sinotubular junction, as well as effective height and coaptation height of aortic valve leaflets, were measured by echography. Transition from the reimplantation to the remodeling configuration was then achieved by longitudinally cutting the skirt of the graft from the annulus to the top of each commissure. The same measurements were then repeated.ResultsAfter transition from the reimplantation to the remodeling configuration, significant increases in the sizes of the aortoventricular junction and of the sinuses were observed. Effective height and coaptation height significantly decreased, and the rounded cross-sectional profile of the aortic valve leaflets flattened.ConclusionsIn the same aortic root, transition from the reimplantation to the remodeling configuration of aortic valve-sparing surgery results in a significant increase in aortic root sizes and in a significant reduction of effective height and coaptation height, suggesting a less satisfactory result.Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.