    Comparison of three haemodynamic monitoring methods in comatose post cardiac arrest patients.

    • Henrik Staer-Jensen, Kjetil Sunde, Espen Rostrup Nakstad, Jan Eritsland, and Geir Øystein Andersen.
    • a Department of Anaesthesiology, Division of Emergencies and Critical Care , Oslo University Hospital , Oslo , Norway.
    • Scand. Cardiovasc. J. 2018 Jun 1; 52 (3): 141-148.

    ObjectivesHaemodynamic monitoring during post arrest care is important to optimise treatment. We compared stroke volume measured by minimally-invasive monitoring devices with or without thermodilution calibration, and transthoracic echocardiography (TTE), and hypothesised that thermodilution calibration would give stroke volume index (SVI) more in agreement with TTE during targeted temperature management (TTM).DesignComatose out-of-hospital cardiac arrest survivors receiving TTM (33 °C for 24 hrs) underwent haemodynamic monitoring with arterial pulse contour analyses with (PiCCO2®) and without (FloTrac®/Vigileo® monitor®) transpulmonary thermodilution calibration. Haemodynamic parameters were collected simultaneously every fourth hour during TTM (hypothermia) and (normothermia). SVI was measured with TTE during hypothermia and normothermia. Bland-Altman analyses were used for determination of SVI bias (±1SD).ResultsTwenty-six patients were included, of whom 77% had initial shockable rhythm and 52% discharged with good outcome. SVI (bias ±2SD) between PiCCO (after thermodilution calibration) vs FloTrac/Vigileo, TTE vs FloTrac/Vigileo and TTE vs PiCCO were 1.4 (±25.8), -1.9 (±19.8), 0.06 (±18.5) ml/m2 during hypothermia and 9.7 (±23.9), 1.0 (±17.4), -7.2 (±12.8) ml/m2 during normothermia. Continuous SVI measurements between PiCCO and FloTrac/Vigileo during hypothermia at reduced SVI (<35 ml/m2) revealed low bias and relatively narrow limits of agreement (0.5 ± 10.2 ml/m2).ConclusionWe found low bias, but relatively wide limits of agreement in SV with PiCCO, FloTrac/Vigileo and TTE during TTM treatment. The methods are not interchangeable. Precision was not improved by transpulmonary thermodilution calibration during hypothermia.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.