• JACC Cardiovasc Interv · May 2009

    Percutaneous device closure of patent foramen ovale in patients with presumed cryptogenic stroke or transient ischemic attack: the Mayo Clinic experience.

    • Monique A Ford, Guy S Reeder, Ryan J Lennon, Robert D Brown, George W Petty, Allison K Cabalka, Frank Cetta, and Donald J Hagler.
    • Division of Cardiovascular Diseases, Mayo Clinic College of Medicine, Rochester, Minnesota 55905, USA.
    • JACC Cardiovasc Interv. 2009 May 1; 2 (5): 404-11.

    ObjectivesWe sought to determine safety, recurrence rates, and novel risk factors for recurrence in patients with cryptogenic stroke/transient ischemic attack (TIA) after patent foramen ovale closure.BackgroundPatent foramen ovale closure in patients with cryptogenic stroke/TIA remains highly controversial. There are limited data on long-term recurrence rates and their predictors in these patients.MethodsThe records of all patients who underwent patent foramen ovale device closure between December 2001 and June 2006 were reviewed. Patients were seen for clinical follow-up at 3 months then followed annually via telephone. Primary end points were recurrent stroke/TIA. Kaplan-Meier methods were used to estimate recurrent event rates. Cox regression analysis was used to identify risk factors for recurrences.ResultsThere were 352 patients with cryptogenic stroke (n = 225) or TIA (n = 118) with a mean age of 53.4 years. The procedural complication rate was 3.4%. Recurrent events occurred in 8 patients: 7 strokes and 2 TIA, 1 patient had 2 recurrent strokes. The recurrence rate was 0.6% and 2.1% for stroke and 0.3% and 0.7% for TIA at 1 and 4 years, respectively. The combined end point of recurrent stroke/TIA occurred at a rate of 0.9% and 2.8% at 1 and 4 years, respectively. Risk factors for recurrences were elevated pulmonary artery pressure (hazard ratio [HR]: 1.12, p = 0.009), elevated right ventricular pressure (HR: 1.09, p = 0.04), factor V Leiden mutation (HR: 7.42, p = 0.014), and protein S deficiency (HR: 12.2, p = 0.002). Residual shunt and atrial septal aneurysm were not associated with recurrences.ConclusionsPatent foramen ovale device closure is safe and is associated with a low recurrence of stroke/TIA. Factors associated with recurrence are thrombophilia and elevated intracardiac pressures.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…