• J Bone Joint Surg Am · May 2019

    Multicenter Study

    Implant Fracture Analysis of the TFNA Proximal Femoral Nail.

    • Anton Lambers, Bertram Rieger, Alan Kop, Peter D'Alessandro, and Piers Yates.
    • Department of Orthopaedic Surgery, Fiona Stanley Hospital, Perth, Western Australia, Australia.
    • J Bone Joint Surg Am. 2019 May 1; 101 (9): 804-811.

    BackgroundMechanical failure of intramedullary nails is rare. This investigation was prompted by a series of cases of observed breakage of the recently introduced TFNA Proximal Femoral Nailing System (TFN [Trochanteric Fixation Nail]-Advanced; DePuy Synthes) in our region. Laboratory analysis and case data are presented, in contribution to post-market surveillance.MethodsMedical and imaging records from the 3 public tertiary orthopaedic trauma hospitals in Western Australia were reviewed. Relevant data of patients in whom breakage of the TFNA implant occurred between 2016 and 2018 were collected and analyzed. Laboratory review of retrieved implants was conducted at the Centre for Implant Technology and Retrieval Analysis (CITRA) in Western Australia.ResultsA total of 16 cases of TFNA implant breakage were recorded and analyzed. The predominant OTA/AO fracture classification was 31A3 (12 cases, 75%). The reduction quality was good in 10 cases, acceptable in 4 cases, and poor in 2 cases. The mean time to failure (and standard deviation) was 5.0 ± 2.2 months (range, 2.2 to 9.8 months). The treatment modality for the breakage was revision nailing in 11 cases, arthroplasty in 3, and nonoperative management in 2. All nails broke at the proximal screw aperture, with 1 nail additionally breaking at the distal aperture. Of 8 patients treated with a second TFNA implant for nail breakage, 3 (38%) returned with breakage of the revision implant. Laboratory analysis of the broken nails demonstrated a unique fracture pattern, with a stepped propagation pathway.ConclusionsThis study represents the largest series, to our knowledge, of proximal femoral nail breakages in the published English literature and is the first that we are aware of to involve laboratory analysis of the TFNA implant. Changes to the nail design and/or alloy may have contributed to the observed cases of breakage, and this study will be followed by an evaluation of breakage rates in comparison with those of previous generations of nailing systems. We advise close clinical and radiographic surveillance of patients with unstable hip fracture patterns who undergo osteosynthesis with use of a TFNA implant.Level Of EvidenceTherapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…